MétaCan
Menu
Back to cohort
Record W2955195295 · doi:10.1111/echo.14409

Accuracy and reliability of qualitative echocardiography assessment of right ventricular size and function in neonates

2019· article· en· W2955195295 on OpenAlexaff
Aisling Smith, Jyothsna R Purna, Michael Castaldo, Daniel Ibarra‐Ríos, Regan E. Giesinger, Danielle R. Rios, Dany E. Weisz, Amish Jain, Afif El‐Khuffash, Patrick J. McNamara

Bibliographic record

VenueEchocardiography · 2019
Typearticle
Languageen
FieldMedicine
TopicPulmonary Hypertension Research and Treatments
Canadian institutionsUniversity of British ColumbiaUniversity of Toronto
FundersNational Heart, Lung, and Blood Institute
KeywordsMedicineCardiologyInternal medicineKappaPulmonary hypertensionVentricular function

Abstract

fetched live from OpenAlex

BACKGROUND: Subjective assessment of right ventricular (RV) function by neonatal echocardiography lacks validation. Incorrect diagnostic assignment in patients with suspected pulmonary hypertension (PH) may lead to unnecessary treatment or missed treatment opportunities. METHODS: Six evaluators (experts [n = 3], novice [n = 3]) were asked to independently rate RV characteristics (global function, dilation, and septal flattening) based on standardized echocardiography images. We randomly selected 60 infants, ≥35 weeks gestation at birth, of whom 30 were clinically unwell with acute pulmonary hypertension (aPH) and 30 were healthy controls. aPH was defined by echocardiography presence of right-left shunting across transitional shunts or elevated right ventricular systolic pressure as estimated by the magnitude of the regurgitant jet across the tricuspid valve with impaired oxygenation. Inter-rater comparative evaluation within groups and between groups was performed using Kappa statistics. RESULTS: Global agreement between evaluators for subjective assessment of RV function (0.3 [0.03], P < 0.001), size (0.14 [0.02], P < 0.001), and septal flattening (0.2 [0.02], P < 0.001) was uniformly poor. Agreement in RV function assessment was marginally better for both expert (0.32 [0.08], P < 0.001 vs 0.13 [0.081], and P < 0.001) and novice (0.4 [0.08], P < 0.001 vs 0.06 [0.07], and P < 0.001) evaluators. Overall, the diagnosis of aPH vs control was misclassified in 18% of cases. CONCLUSION: This study demonstrated significant variability in qualitative assessment of RV size and function by trained evaluators, regardless of level of expertise attained. The reliability of objective measures of RV hemodynamics requires prospective evaluation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.041
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.055

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0100.041
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.327
Teacher spread0.313 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations42
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueEchocardiographySame topicPulmonary Hypertension Research and TreatmentsFrench-language works237,207