MétaCan
Menu
Back to cohort
Record W2959811505 · doi:10.1002/hed.25864

The image‐guided operating room—Utility and impact on surgeon's performance in the head and neck surgery

2019· article· en· W2959811505 on OpenAlexafffund
Nidal Muhanna, Catriona M. Douglas, Michael J. Daly, Harley Chan, Robert Weersink, Jimmy Qiu, Jason L. Townson, John R. de Almeida, David P. Goldstein, Ralph Gilbert, Eugene Yu, Walter Kucharczyk, David A. Jaffray, Jonathan C. Irish

Bibliographic record

VenueHead & Neck · 2019
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsMount Sinai HospitalSinai Health SystemPrincess Margaret Cancer CentreUniversity of TorontoUniversity Health Network
FundersPrincess Margaret Cancer Foundation
KeywordsMedicineImage qualityNeurosurgeryRadiologyArtifact (error)Head and neckCardiothoracic surgeryImage-guided surgerySurgeryNuclear medicineMedical physicsArtificial intelligence

Abstract

fetched live from OpenAlex

BACKGROUND: The image-guided operating room (OR) is an emerging standard for dealing with complex cases in many surgical disciplines including neurosurgery, thoracic surgery, maxillofacial trauma, and orthopedic surgery. Its use in head and neck oncological surgery is not well established. The primary aim of this study was to assess the image quality of cone-beam CT (CBCT) under real clinical conditions. The secondary aim was to assess the effect on surgical performance and decision making. METHODS: Intraoperative 3D imaging was performed using a CBCT capable C-Arm mounted on a multi-axis robot (Siemens Zeego) in the image-guided OR. All patients had immediate preoperative imaging taken with further intraoperative imaging performed as required. Ten initial patients, comprising 28 intraoperative scans, were used for questionnaire-based image reviews conducted with experienced head and neck clinicians. Scans were assessed for aspects of both image quality and clinical utility, on separate 5-point Likert scales (1-5). RESULTS: ) from 1 to 3 with the use of IV contrast (region of interest CT# was 284 HU [SD, 47 HU]). Images were rated as 4 for freedom from artifact. Soft tissue definition was 2, with no significant improvement (P = .2) with the addition of IV iodinated contrast. Surgeons rated the greatest clinical utility (4) for the CBCT when assessing postreconstruction imaging of a complex case. CONCLUSIONS: The image quality of CBCT in the image-guided OR is good for bony detail and complex oncological reconstructions in the head and neck setting but probably has limited benefit for intraoperative soft tissue delineation. Future studies must also focus on clinical outcomes to help demonstrate the value of the image-guided OR.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.013
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.013
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.304
Teacher spread0.288 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueHead & NeckSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207