MétaCan
Menu
Back to cohort
Record W2960426091 · doi:10.2196/14443

Modular Catheter Systems in Minimally Invasive Interventional Medical Procedures: Case Study

2019· article· en· W2960426091 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

venuePublished in a venue whose home country is Canada.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueJMIR Biomedical Engineering · 2019
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsnot available
Fundersnot available
KeywordsModular designMedicineCatheterAngioplastyAdapter (computing)BalloonBalloon catheterSurgeryRadiologyComputer scienceComputer hardwareOperating system

Abstract

fetched live from OpenAlex

Background Medical device catheters that are used in minimally invasive interventional medical procedures all follow the same integrated design and use paradigm. The features and elements of any catheter device are combined in a single unitary construction. A modular approach to the design, construction, and use of these types of interventional catheters may provide significant advantages and benefits not available with an integrated design paradigm. Objective This paper aimed to present the design of a modular catheter system and the findings from an initial veterinary use as a case study for the potential of modular catheter systems in general. Methods A modular catheter system was designed using commercially available angioplasty balloon dilatation catheters as one module in the system and a custom designed scoring adapter as the other module. The scoring adapter incorporates wires to add scoring features to the angioplasty balloon catheter to improve the dilatation performance during a pulmonary valvuloplasty procedure. The scoring adapter also includes a novel attachment mechanism to couple the scoring adapter to any 0.035-inch guidewire–compatible angioplasty balloon catheter. Results The modular catheter system was successfully designed, manufactured, and used in an initial minimally invasive veterinary cardiovascular intervention to treat a case of canine subvalvular pulmonary stenosis. The scoring adapter and angioplasty balloon catheter were successfully combined tableside in the operating room at the time of the procedure and used to successfully dilate the subvalvular obstruction. Conclusions The successful design and use of the presented modular catheter system demonstrates the feasibility and potential advantages of this type of paradigm to enable physicians to create interventional catheter devices at the time of a procedure guided by the procedural needs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.063
Threshold uncertainty score0.665

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.313
Teacher spread0.304 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it