MétaCan
Menu
Back to cohort
Record W2963947834 · doi:10.1002/cre2.198

Corrosion resistance of coupled sandblasted, large‐grit, acid‐etched (SLA) and anodized Ti implant surfaces in synthetic saliva

2019· article· en· W2963947834 on OpenAlexfundno aff
Ala'a Al Otaibi, El‐Sayed M. Sherif, Mohammed Q. AlRifaiy, Spiros Zinelis, Youssef S. Al Jabbari

Bibliographic record

VenueClinical and Experimental Dental Research · 2019
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
FundersInstitute of Population and Public HealthKing Saud University
KeywordsCorrosionMaterials scienceDielectric spectroscopyImplantPitting corrosionGalvanic corrosionMetallurgyElectrochemistryPolarization (electrochemistry)ChemistryElectrodeSurgeryMedicine

Abstract

fetched live from OpenAlex

Purpose: The purpose of this study was to investigate the corrosion resistance of galvanically coupled SLA and anodized implant surfaces with a Co-Cr alloy. Materials and Methods: Three groups were included in this study. The first (SLA) was composed of SLA implants (Institut Straumann, Basel, Switzerland), the second (ANO) of NobelReplace® (Nobel Biocare, Göteborg, Sweden), and the third (MIX) of both implant systems combined. All groups were assembled with a single Co-Cr superstructure. Electrochemical testing included open-circuit potential, electrochemical impedance spectroscopy, cyclic potentiodynamic polarization, and chronoamperometric current-time measurements. The quantitative results (EOCP, ECORR, ICORR, EPROT, RP, and ICA) were statistically analyzed by one-way ANOVA and Tukey's post-hoc multiple comparison test (α = 0.05). Results: All the aforementioned parameters showed statistically significant differences apart from ECORR and EPROT. The evaluation of qualitative and quantitative results showed that although SLA had higher corrosion resistance compared with ANO, it had less resistance to pitting corrosion. This means that SLA showed increased resistance to uniform corrosion but less resistance if pitting corrosion was initiated. In all cases, MIX showed intermediate behavior. Conclusion: The corrosion resistance of implant-retained superstructures is dependent on the electrochemical properties of the implants involved, and thus different degrees of intraoral corrosion resistance among different implant systems are anticipated.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.072
Threshold uncertainty score0.798

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.073
GPT teacher head0.444
Teacher spread0.371 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueClinical and Experimental Dental ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207