MétaCan
Menu
Back to cohort
Record W2965711491 · doi:10.19102/icrm.2018.090603

A Comparison of the Efficacy of Voltage-directed Cavotricuspid Isthmus Ablation Using Mini Versus Conventional Electrodes

2018· article· en· W2965711491 on OpenAlexaff
Riyaz Somani, G. André Ng, N. Hobson, D. Redfearn, Jane C. Caldwell

Bibliographic record

VenueJournal of Innovations in Cardiac Rhythm Management · 2018
Typearticle
Languageen
FieldMedicine
TopicCardiac Arrhythmias and Treatments
Canadian institutionsQueen's University
FundersSt. Jude MedicalBoston Scientific CorporationAbbott Laboratories
KeywordsAtrial flutterAblationCatheterFluoroscopyCatheter ablationMedicineFlutterBlock (permutation group theory)ElectrodeVoltageCardiologyRadiofrequency ablationNuclear medicineInternal medicineBiomedical engineeringMaterials scienceSurgeryMathematicsChemistryElectrical engineeringPhysics

Abstract

fetched live from OpenAlex

Cavotricuspid isthmus (CTI) ablation is a current first-line management method for typical atrial flutter. A voltage-directed technique that systematically targets points of maximal voltage has be found to reduce procedure and fluoroscopy times without increasing recurrence. We hypothesized that this technique's efficiency would be enhanced by using signals from radial minielectrodes of a novel catheter (IntellaTip MiFi™; Boston Scientific, Natick, MA, USA). Prospectively, atrial flutter patients underwent voltage-directed ablation with a nonirrigated 8-mm-tip catheter. Ablation was either directed by conventional bipolar electrodes (group A, n = 13) or mini-electrodes (group B, n = 17) with the goal of achieving bidirectional block at the CTI and a subsequent observation time of 30 minutes. Total radiofrequency application time and lesion numbers were not significantly different. Group B had a lower mean power [38.7 watts (W) ± 2.0 W versus 44.8 W ± 1.9 W; p < 0.05] and a tendency for longer fluoroscopy and procedure times. In three of the cases in group B, a switch to an irrigated catheter was required in order to achieve bidirectional block. In group A, bidirectional block was obtained in all patients using the nonirrigated catheter with no significant increase in reconnection. Differences in the catheter performance between the two groups were driven by poorer performance of the MiFi™ catheter (Boston Scientific, Natick, MA, USA) in patients presenting in atrial flutter. Electroanatomical mapping revealed a more proximal localization of the maximal voltage by the minielectrodes as compared with the conventional bipolar electrodes, resulting in less efficient identification and ablation of the conducting muscle bundles. Final results indicated CTI ablation using minielectrodes is not superior to conventional bipolar electrodes in the use of 8-mm, nonirrigated electrodes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.037
GPT teacher head0.354
Teacher spread0.316 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Innovations in Cardiac Rhythm ManagementSame topicCardiac Arrhythmias and TreatmentsFrench-language works237,207