MétaCan
Menu
Back to cohort

Transcatheter Aortic Valve Replacement With the HLT Meridian Valve

2019· article· en· W2967611624 on OpenAlexaffabout
Josep Rodés‐Cabau, Mathew Williams, Harindra C. Wijeysundera, Dean J. Kereiakes, Jean‐Michel Paradis, Cezar Staniloae, Muhamed Sarić, Sam Radhakrishnan, Robert F. Wilson, Spencer H. Kubo

Bibliographic record

VenueCirculation Cardiovascular Interventions · 2019
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsSunnybrook Health Science Centre
Fundersnot available
KeywordsMedicineCardiac skeletonCardiologyInternal medicineStenosisAortic valve replacementRegurgitation (circulation)Aortic valveSurgeryValve replacementAortic valve stenosis

Abstract

fetched live from OpenAlex

BACKGROUND: While most self-expanding transcatheter valves are repositionable, only one fully retrievable valve is currently available. The Meridian valve is a new self-expanding valve with full retrievability properties. The objective of our study was to evaluate the early feasibility, preliminary safety, and efficacy of transcatheter aortic valve replacement with the HLT Meridian valve (HLT, Inc). METHODS: This was a multicenter early feasibility study including patients with severe aortic stenosis at high surgical risk undergoing transfemoral transcatheter aortic valve replacement with the 25-mm Meridian valve. All serious adverse events were adjudicated by an independent clinical events committee according to Valve Academic Research Consortium-2 criteria. Echocardiography data were assessed by an independent echocardiography core laboratory. RESULTS: A total of 25 patients (mean age, 85±6 years; 80% of men) were included. The valve was successfully implanted in 22 (88%) patients (annulus too large and extreme horizontal aorta in 2 and 1 unsuccessful cases, respectively). Valve retrieval because of an initial nonadequate positioning was attempted and successfully performed in 10 (40%) patients. Echocardiography post-transcatheter aortic valve replacement showed a low mean residual gradient (10±4 mm Hg) and the absence of moderate-severe aortic regurgitation (none-trace and mild aortic regurgitation in 76% and 24% of patients, respectively). Mortality at 30 days was 8%, with no cases of disabling stroke, valve embolization, or major/life-threatening bleeding complications. At 6-month follow-up, the cumulative mortality rate was 12%, with no changes in echocardiographic parameters and no cases of valve dysfunction. The majority of patients (89%) were in New York Heart Association class I-II at 6 months. CONCLUSIONS: Transcatheter aortic valve replacement with the Meridian valve was feasible and associated with acceptable early and 6-month clinical results. Valve retrieval after full valve deployment was successfully performed in all attempted cases, and valve performance was excellent, with low residual gradients, no cases of moderate-severe aortic regurgitation, and none-trace residual aortic regurgitation in the majority of patients. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02838680 (RADIANT-Canada); NCT02799823 (RADIANT-US).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (broad)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.217
Threshold uncertainty score0.985

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.024
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.305
Teacher spread0.284 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2019
Admission routes2
Has abstractyes

Explore more