MétaCan
Menu
Back to cohort
Record W2967687587 · doi:10.1117/12.2526079

Dosimetry recommendations for NMIBC: a simulation and in vivo study (Conference Presentation)

2019· article· en· W2967687587 on OpenAlexaff
Lothar Lilge, Daniel Molehuis, Angelica Manalac, Fynn Schwiegelshohn, Vaughn Betz, Wayne Embree, Arkady Mandel, Roger Dumoulin-White, Girish Kulkani, Michael A.S. Jewett

Bibliographic record

Venue17th International Photodynamic Association World Congress · 2019
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsMcMaster UniversityUniversity of TorontoUniversity Health Network
Fundersnot available
KeywordsPresentation (obstetrics)DosimetryComputer scienceMedical physicsPhysicsMedicineNuclear medicine

Abstract

fetched live from OpenAlex

Recurrent Non-Muscle Invasive Bladder Cancer (NMIBC) is a diffuse disease, and patients have failed standard BCG therapy face prophylactic cystectomy. PDT fell out of favour due to its variable outcome, and high morbidity. To overcome PDT associate toxicity to the bladder’s muscle layer, the use of shorter wavelength and instillation of the photosensitizer were suggested. While either approach was shown to improve the outcome in animal models they have not previously combined in human studies. Additionally, the effects of highly variable tissue optical properties of the bladder and its shape have not been studied. Here, we present surface dose histograms derived from light propagation simulation in 6 human bladders using CT images for anatomical detail and the FullMonte software package. The ability of a single light sensor versus 3 or 12 light sensors to measure the average irradiance on the bladder surface was evaluated as a function of the bladder wall’s tissue optical properties. Results show that the irradiance in non-spherical bladders can vary over an order of magnitude, but the irradiance histograms are affected little by displacement of the emitter inside the bladder void. As the surface area monitored by a single sensor depends strongly on the bladder shape, the responsivity of a single sensor to the average bladder irradiance can vary equally. Twelve light sensors monitor the entire bladder surface almost complete and hence their average responsivity is constant to the average irradiance on the bladder largely independent of shape. The dependency of the sensor’s response on the tissue optical properties is also lower.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.866
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.339
Teacher spread0.326 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2019
Admission routes1
Has abstractyes

Explore more

Same venue17th International Photodynamic Association World CongressSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207