MétaCan
Menu
Back to cohort
Record W2968004994 · doi:10.1002/ejhf.1568

Cardiac Implantable Electronic Devices with a Defibrillator Component and All-Cause Mortality in Left Ventricular Assist Device Carriers: Results from the PCHF-VAD Registry

2019· article· en· W2968004994 on OpenAlexaff
Maja Čikeš, Nina Jakuš, Brian Claggett, Jasper J. Brugts, Philippe Timmermans, Anne–Catherine Pouleur, Paweł Rubiś, Emeline M. Van Craenenbroeck, Edvinas Gaizauskas, Sebastian Grundmann, Stefania Paolillo, Eduardo Barge‐Caballero, Domenico D’Amario, Aggeliki Gkouziouta, Ivo Planinc, Jesse F. Veenis, Luc‐Marie Jacquet, Laura Houard, Katarzyna Holcman, Arno Gigase, Filip Rega, Kęstutis Ručinskas, S. Adamopoulos, Piergiuseppe Agostoni, Bojan Biočina, Hrvoje Gašparović, Lars H. Lund, Andreas J. Flammer, Marco Metra, Davor Miličić, Frank Ruschitzka

Bibliographic record

VenueEuropean Journal of Heart Failure · 2019
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsSurgical Specialties (Canada)
FundersRelypsaTufts University School of MedicineServierUniversität ZürichHeartWareSveučilište u ZagrebuAlnylam PharmaceuticalsUniversità degli Studi di BresciaPfizerVifor PharmaTeva Pharmaceutical IndustriesSanofiBristol-Myers SquibbAstraZenecaAmgen
KeywordsMedicineInterquartile rangeImplantable cardioverter-defibrillatorHazard ratioCardiologyCardiac resynchronization therapyInternal medicineVentricular assist deviceDefibrillationConfidence intervalHeart failureImplantEjection fractionSurgery

Abstract

fetched live from OpenAlex

AIMS: To compare characteristics of left ventricular assist device (LVAD) recipients receiving a cardiac implantable electronic device (CIED) with a defibrillator component (implantable cardioverter-defibrillator and cardiac resynchronization therapy with defibrillation, CIED-D) vs. those without one, and to assess whether carrying such a device contiguously with an LVAD is associated with outcomes. METHODS AND RESULTS: Overall, 448 patients were analysed (mean age 52 ± 13 years, 82% male) in the multicentre European PCHF-VAD registry. To account for all active CIED-Ds during ongoing LVAD treatment, outcome analyses were performed by a time-varying analysis with active CIED-D status post-LVAD as the time-varying covariate. At the time of LVAD implantation, 235 patients (52%) had an active CIED-D. Median time on LVAD support was 1.1 years (interquartile range 0.5-2.0 years). A reduction of 36% in the risk of all-cause mortality was observed in patients with an active CIED-D [hazard ratio (HR) 0.64, 95% confidence interval (CI) 0.46-0.91; P = 0.012), increasing to 41% after adjustment for baseline covariates (HR 0.59, 95% CI 0.40-0.87; P = 0.008) and 39% after propensity score adjustment (HR 0.61, 95% CI 0.39-0.94; P = 0.027). Other than CIED-D, age, LVAD implant as redo surgery, number of ventricular arrhythmia episodes and use of vasopressors pre-LVAD were remaining significant risk factors of all-cause mortality. Incident ventricular arrhythmias post-LVAD portended a 2.4-fold and 2.6-fold increased risk of all-cause and cardiovascular death, respectively; carrying an active CIED-D remained associated with a 47% and 43% reduction in these events, respectively. CONCLUSIONS: In an analysis accounting for all active CIED-Ds, including those implanted during LVAD support, carrying such a device was associated with significantly better survival during LVAD support.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.478
Threshold uncertainty score0.712

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.217
Teacher spread0.204 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations40
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Journal of Heart FailureSame topicMechanical Circulatory Support DevicesFrench-language works237,207