MétaCan
Menu
Back to cohort
Record W2969372464 · doi:10.1186/s41824-019-0061-7

Assessment of a novel 32-channel phased array for cardiovascular hybrid PET/MRI imaging: MRI performance

2019· article· en· W2969372464 on OpenAlexafffund
Adam Farag, Robert T. Thompson, Jonathan D. Thiessen, John Butler, Frank S. Prato, Jean Théberge

Bibliographic record

VenueEuropean Journal of Hybrid Imaging · 2019
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsLawson Health Research InstituteWestern University
FundersMitacsCanada Foundation for Innovation
KeywordsPhased arrayImaging phantomMagnetic resonance imagingPositron emission tomographyCorrection for attenuationImage qualitySignal-to-noise ratio (imaging)Nuclear medicineBiomedical engineeringPhysicsMedicineComputer scienceOpticsRadiologyTelecommunicationsArtificial intelligence

Abstract

fetched live from OpenAlex

BACKGROUND: Cardiovascular imaging using hybrid positron emission tomography (PET) and magnetic resonance imaging (MRI) requires a radio frequency phased array resonator capable of high acceleration factors in order to achieve the shortest breath-holds while maintaining optimal MRI signal-to-noise ratio (SNR) and minimum PET photon attenuation. To our knowledge, the only two arrays used today for hybrid PET/MRI cardiovascular imaging are either incapable of achieving high acceleration or affect the PET photon count greatly. PURPOSE: This study is focused on the evaluation of the MRI performance of a novel third-party prototype 32-channel phased array designed for simultaneous PET/MRI cardiovascular imaging. The study compares the quality parameters of MRI parallel imaging, such as g-factor, noise correlation coefficients, and SNR, to the conventional arrays (mMR 12-channel and MRI-only 32-channel) currently used with hybrid PET/MRI systems. The quality parameters of parallel imaging were estimated for multiple acceleration factors on a phantom and three healthy volunteers. Using a Germanium-68 (Ge-68) phantom, preliminary measurements of PET photon attenuation caused by the novel array were briefly compared to the photon counts produced from no-array measurements. RESULTS: produced by the novel 32-channel PET/MRI array were better than those produced by the MRI-only 32-channel array by 5% or more. The novel array has resulted in MRI SNR improvements of > 30% at all acceleration factors, in comparison to the mMR12-channel array. Preliminary evaluation of PET transparency showed less than 5% photon attenuation caused by both anterior and posterior parts of the novel array. CONCLUSIONS: The MRI performance of the novel PET/MRI 32-channel array qualifies it to be a viable alternative to the conventional arrays for cardiovascular hybrid PET/MRI. A detailed evaluation of the novel array's PET performance remains to be conducted, but cursory assessment promises significantly reduced attenuation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.710
Threshold uncertainty score0.882

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.291
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueEuropean Journal of Hybrid ImagingSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207