MétaCan
Menu
Back to cohort
Record W2969837141 · doi:10.1002/jbm.b.34470

CoCrMo metal release in metal‐on‐highly crosslinked polyethylene hip implants

2019· article· en· W2969837141 on OpenAlexafffund
Qiong Wang, Felipe Eltit, Donald S. Garbuz, Clivе P. Duncan, Bassam A. Masri, Nelson V. Greidanus, Rizhi Wang

Bibliographic record

VenueJournal of Biomedical Materials Research Part B Applied Biomaterials · 2019
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsUniversity of British Columbia
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health Research
KeywordsTribocorrosionFrettingCorrosionMaterials sciencePeriprostheticMetalPolyethyleneCrevice corrosionMetallurgyMedicineComposite materialSurgeryArthroplastyChemistry

Abstract

fetched live from OpenAlex

Increasing cases of adverse local tissue reactions (ALTRs) associated with metal release have been observed in patients with metal-on-highly crosslinked polyethylene (MoP) hip implants, the most common design in total hip replacements. Studies have demonstrated the metal release from fretting corrosion at the head-neck junction, but rarely investigated tribocorrosion associated metal release at articulating surfaces in MoP hip implants. The objective of this study is to investigate both tribocorrosion at the articulating surfaces and fretting corrosion at the head-neck junction in CoCrMo femoral heads, as well as their association with metal species released in periprosthetic tissues and body fluids in MoP hip systems. Twenty-three patients with ALTRs associated with MoP implants were included. Systematic analyses were performed on the wear damage in articulation, corrosion at the head-neck junction and their correlation with degradation products observed in synovial fluid, periprosthetic tissues, and serum. Results showed that tribocorrosion at the articulating surfaces contributed to the elevated concentration of both Co and Cr ions in serum, while fretting corrosion at the head-neck junction mainly released Co ions to serum. Both tribocorrosion at the articulating surfaces and fretting corrosion at the head-neck junction released particles rich in chromium and phosphate, the dominant particles found in synovial fluids and tissues. This study provides strong evidence that tribocorrosion at the articulating surfaces in MoP hip implants could result in significant metal release. This information should be taken into account when studying the mechanisms of ALTRs and developing strategies of preventing metal release in total hip replacements.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.000
Threshold uncertainty score0.001

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.049
GPT teacher head0.357
Teacher spread0.308 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations28
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Biomedical Materials Research Part B Applied BiomaterialsSame topicOrthopaedic implants and arthroplastyFrench-language works237,207