MétaCan
Menu
← Back to cohort
Record W2971286295 · doi:10.1111/cid.12842

In vitro comparison of resonance frequency analysis devices to evaluate implant stability of narrow diameter implants at varying drilling speeds in dense artificial bone blocks

2019· article· en· W2971286295 on OpenAlexvenueno aff
Georgios E. Romanos, Daniel J. Bastardi, Apoorv Kakar, Rachel Moore, Rafael Delgado-Ruíz, Fawad Javed

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2019
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsResonance frequency analysisImplant stability quotientImplantDentistryArtificial boneMaterials scienceOrthodonticsOsseointegrationSignificant differenceMedicineBiomedical engineeringSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: There are no studies that have assessed the implant stability quotient (ISQ) values of narrow diameter implants placed in artificial dense bone blocks at varying drilling speeds (DSs). PURPOSE: The aim of the present in vitro experiment was to compare the performance of OSSTELL and Penguin devices to evaluate implant stability at DSs of 800 and 2000 rpm. MATERIALS AND METHODS: A total of 360 osteotomies were created in dense artificial bone blocks at DSs of 800 and 2000 rpm. Dental implants from three manufacturers (group-1: NobelActive implants, Nobel Biocare, Yorba Linda, California; group-2: Zimmer, Eztetic-Zimmer implants, Zimmer Biomet Dental, Palm Beach Gardens, Florida; and group-3: Astra Tech implant system, Dentsply Sirona, York, Pennsylvania) were randomly placed in these osteotomies using an insertion torque of 15 Ncm (60 implants/group). Implant stability in all bone blocks immediately following implant placement was evaluated using the OSSTELL and Penguin devices. ISQ values were presented as means ± SD. Statistical significance was set at P < .05. RESULTS: There was no significant difference in the ISQ values obtained from the OSSTELL and Penguin devices for implants in groups 1, 2, and 3. There was no significant difference when ISQ values obtained from the OSSTELL device were compared with the Penguin device for narrow diameter dental implants placed in dense bone blocks with osteotomies performed at 800 and 2000 rpm. ISQ values showed statistically significant higher values for OSSTELL compared to Penguin device. CONCLUSION: The OSSTELL and Penguin devices are reliable for the assessment of implant stability in dense artificial bone. Implant design and site-DS does not seem to have a significant impact of implant stability in artificial dense bone blocks.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.159
GPT teacher head0.479
Teacher spread0.320 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→