MétaCan
Menu
Back to cohort

Recanalization of CTOs with SoundBite™ Active Wire

2018· article· en· W2971532914 on OpenAlexaffabout
Marianne Brodmann, Éric Thérasse, Andrew Benko, Louis-Philippe Riel, Steven Dion, Philippe Généreux, Martin Brouillette

Bibliographic record

VenueThe Journal of Cardiovascular Surgery · 2018
Typearticle
Languageen
FieldMedicine
TopicPeripheral Artery Disease Management
Canadian institutionsHôpital du Sacré-Cœur de MontréalUniversité de SherbrookeUniversité de Montréal
Fundersnot available
KeywordsMedicineSurgeryAnkleOcclusionPerforationRevascularizationClaudicationAdverse effectArterial diseaseRadiologyMyocardial infarctionCardiologyInternal medicineVascular disease

Abstract

fetched live from OpenAlex

BACKGROUND: The aim of this study was to examine the safety and efficacy of the SoundBite™ Crossing System for the recanalization of infrainguinal chronic total occlusion (CTO) lesions. CTOs are frequent among patients with severe claudication or critical limb ischemia. Failure to recanalize CTOs remains common and is associated with poor prognosis. The SoundBite™ Crossing System (SoundBite Medical Solutions Inc., Montreal, QC, Canada) is a newly developed device that uses a 0.018-inch wire (SoundBite™ Active Wire) to deliver acoustic shock waves to the distal tip of a steerable guidewire to facilitate directed penetration of the proximal cap and crossing of the occlusion. METHODS: Symptomatic patients with de novo infrainguinal CTOs from 3 centers were enrolled in a prospective, single-arm feasibility study. The primary endpoint was 30-day device success defined as composite of technical success, defined as penetration and progression within the CTO with the SoundBite™ Active Wire followed by complete recanalization, and freedom from device-related major adverse events including death, urgent amputation, clinically-driven target vessel revascularization, perforation, type ≥C dissection, or distal embolization requiring intervention. RESULTS: Thirty-seven patients including 41 CTO lesions were enrolled in this study. CTO length ranged from 10 mm to 270 mm (mean 97.9±77.4 mm), and moderate-to-severe calcification was present in 24 (58.5%) of the treated lesions. CTOs were successfully crossed in 34 (91.9%) patients. No device-related adverse events occurred, resulting in a 30-day device success rate of 91.9%. Compared with baseline, 30-day ankle brachial index (0.66±0.24 versus 0.89±0.20; P<0.001) and Rutherford class (3 [2, 4] versus 0 [0, 1], P<0.001) significantly improved. CONCLUSIONS: The SoundBite™ Active Wire Crossing System feasibility study demonstrates a favorable safety and efficacy profile for the SoundBite™ Active Wire in infrainguinal CTOs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.604
Threshold uncertainty score0.238

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.225
Teacher spread0.210 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueThe Journal of Cardiovascular SurgerySame topicPeripheral Artery Disease ManagementFrench-language works237,207