MétaCan
Menu
Back to cohort
Record W2971891148 · doi:10.3389/fvets.2019.00312

Intraosseous Catheter Flow Rates and Ease of Placement at Various Sites in Canine Cadavers

2019· article· en· W2971891148 on OpenAlexafffund
James C. Lange, Søren Boysen, Adam J. Bentley, Aylin Atilla

Bibliographic record

VenueFrontiers in Veterinary Science · 2019
Typearticle
Languageen
FieldMedicine
TopicCardiac Arrest and Resuscitation
Canadian institutionsUniversity of Calgary
FundersUniversity of Calgary
KeywordsMedicineFemurTibiaHumerusCadaverCatheterSurgeryAnesthesiaAnatomy

Abstract

fetched live from OpenAlex

Objective – To compare intraosseous catheter placement difficulty, success rates, and flow rates at four different locations in canine cadavers. Design – Prospective study. Setting – Private referral centre. Animals - Fresh canine cadavers. Interventions – With owner consent, animals presenting for euthanasia were recruited. Animals received heparin (1000IU/kg IV) at least five minutes prior to euthanasia. After euthanasia, EZIO intraosseous catheters were placed into the ilial wing, proximal medial tibia, proximal lateral humerus and distal lateral femur on one side of the animal. Time to catheter placement and catheter difficulty were scored for each placement site. Sterile saline was infused into each location simultaneously over five minutes, first via gravity then using 300mmHg pressure. Animals were repositioned onto the contra-lateral side and the experiment repeated. Measurements and Main Results – Placement was successful in 16/22 ilial, 18/22 tibial, and 22/22 femoral and humoral attempts. A post hoc analysis revealed the ileum had a significantly greater difficulty score when compared to the femur and humerus (p ≤ 0.0001). There was a statistically significant difference in placement time between the femur and the ileum (p ≤ 0.05). Gravity infusion rates in the tibia were statistically lower than the humerus (p≤0.01) and between the tibia and the femur (p ≤0.001). Additionally, pressurized infusion rates were statistically lower in the tibia compared to the humerus (p ≤0.0001), the femur (p ≤0.0001) and the ileum (p ≤0.01). Conclusions – The femur and humerus had high success rate for IO catheter placement and low placement time and difficulty scores. Pressurized intraosseous flow rates were highest in the humerus and femur. Contrary to human literature, success rates for catheter placement in the humerus and femur were higher than at other sites, suggesting the humerus and femur may be preferred sites for intraosseous catheter placement in the dog. Further investigation through a larger sample size is required to confirm these findings.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.094
Threshold uncertainty score0.308

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.258
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueFrontiers in Veterinary ScienceSame topicCardiac Arrest and ResuscitationFrench-language works237,207