MétaCan
Menu
Back to cohort
Record W2972388519 · doi:10.1002/jmri.26924

Relative Magnetic Force Measures and Their Potential Role in MRI Safety Practice

2019· article· en· W2972388519 on OpenAlexaff
Lawrence P. Panych, Vera Kimbrell, Srinivasan Mukundan, Bruno Madore

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2019
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsWestern University
Fundersnot available
KeywordsMagnetic fieldMagnetImaging phantomFerromagnetismMagnetostaticsElectromagnetPhysicsComputer scienceCondensed matter physicsOptics

Abstract

fetched live from OpenAlex

BACKGROUND: Magnetic field markings are occasionally used at MRI sites to provide visual feedback of magnetic field strength at locations within the MRI scan room for safety purposes. In addition to magnetic field line markings, relative magnetic force, or ratio of magnetic to gravitational forces on an object, may be considered a useful complementary metric to quantify the risk associated with bringing objects containing ferromagnetic material into the magnetic field. PURPOSE: To develop and validate methods for deriving useful relative magnetic-force measures including a simple force index for application to MRI safety. STUDY TYPE: Phantom. PHANTOM: A special-purpose rig was built to experimentally measure relative magnetic forces on small ferromagnetic objects. FIELD STRENGTH: Ranging from 1.5T to 7T. ASSESSMENT: Quantitative comparisons were made between theoretical and measured relative magnetic forces on six objects containing ferromagnetic material: a piece of iron, a paper clip, a Kelly clamp, nail clippers, a cell phone, and a small permanent magnet. STATISTICAL TESTS: An analysis based on the Bland-Altman method was employed. RESULTS: After correction of the 1.5T data to account for assumed positioning errors of the test rig, limits of agreement between measured and estimated relative forces in the four MRI systems were ±0.16, where a relative force of 1.0 indicates that the magnetic force is equal to gravitation force. There was no significant bias in the data (P < = 0.05). DATA CONCLUSION: Accurate measures of relative magnetic forces on ferromagnetic objects can be derived for MRI safety purposes. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;51:1260-1271.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.042
metaresearch head score (Gemma)0.178
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.042
Threshold uncertainty score0.222

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0420.178
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0050.003
Science and technology studies0.0010.004
Scholarly communication0.0030.004
Open science0.0020.002
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.267
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207