MétaCan
Menu
Back to cohort
Record W2977265968 · doi:10.1109/jsen.2019.2945003

Quasi-D-Shaped Fiber Optic Plasmonic Biosensor for High-Index Analyte Detection

2019· article· en· W2977265968 on OpenAlexafffund
Yashar E. Monfared, Morteza Hajati, Chunhao Liang, Shunchuan Yang, Montasir Qasymeh

Bibliographic record

VenueIEEE Sensors Journal · 2019
Typearticle
Languageen
FieldEngineering
TopicAdvanced Fiber Optic Sensors
Canadian institutionsDalhousie University
FundersKillam TrustsDalhousie University
KeywordsAnalyteBiosensorRefractive indexSurface plasmon resonanceMaterials scienceSensitivity (control systems)Analytical Chemistry (journal)PlasmonOpticsOptoelectronicsChemistryNanotechnologyNanoparticlePhysicsChromatographyElectronic engineering

Abstract

fetched live from OpenAlex

In this paper, we propose a highly sensitive quasi-D-shaped fiber optic biosensor for detection of high refractive index (RI) liquid analytes via surface plasmon resonance. The main mechanism of sensing is interplay between photonic crystal fiber fundamental mode and plasmonic mode which leads to formation of different resonance peaks depending on the analyte RI. We numerically analyze the structure sensitivity to design parameters and demonstrate the sensing performance of the proposed biosensor using both spectral sensitivity and amplitude sensitivity methods. The proposed biosensor has a RI detection range of 0.15 refractive index unit (RIU) from 1.45 to 1.6. The sensor exhibits linear sensing performance with a RI spectral sensitivity of 9300 nm/RIU for analyte RI ranging from 1.45 to 1.525, 1176 nm/RIU for analyte RI ranging from 1.525 to 1.6 and in particular, 11800 nm/RIU for analyte RI between 1.475 and 1.5. Furthermore, an average RI sensitivity of 4800 nm/RIU for analyte RI ranging from 1.45 to 1.6 is demonstrated. We also study the amplitude sensitivities of the proposed sensor which show promising maximum values of 183.6 RIU <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> for 785 nm excitation and 820 RIU <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> for 1050 nm excitation. Due to the simple structure of the proposed biosensor, large detection range, high sensitivity and promising linear sensing performance, the proposed biosensor can be a promising candidate for detecting various high RI chemical and biochemical samples.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Direct model labels (unvalidated)

Per-model category and study-design labels from the labeling rounds. They are machine output, unvalidated, and the disagreement between models ships as data. No study design here is MEDLINE-validated yet.

Model armCategoriesStudy designConfidence
gemmano category
Domain: not available · Genre: Empirical
About the Canadian research system: no · About a Canadian topic: no
Bench or experimentallow
gptno category
Domain: not available · Genre: Empirical
About the Canadian research system: no · About a Canadian topic: no
Bench or experimentalhigh
models agreeAgreement compares identical category sets and study designs across arms.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.013
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.225
Teacher spread0.216 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Labeled directly by 2 models reading the full record.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations43
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Sensors JournalSame topicAdvanced Fiber Optic SensorsFrench-language works237,207