MétaCan
Menu
Back to cohort
Record W2977836980 · doi:10.29173/aar64

Design of a Braided Composite Badminton Racket on Solidworks

2019· article· en· W2977836980 on OpenAlexaffvenue
Mackenzie Neufeld, Ahmed Samir Ead, Eric Lepp

Bibliographic record

VenueAlberta Academic Review · 2019
Typearticle
Languageen
FieldEngineering
Topic3D Shape Modeling and Analysis
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsKevlarBraidEllipseMandrelComposite materialRacketMaterials scienceThermoplasticStructural engineeringEngineering drawingComposite numberEngineeringMechanical engineeringSwingGeometryMathematics

Abstract

fetched live from OpenAlex

Current badminton rackets are typically made out of steel, aluminium, or carbon fibre. Although these materials perform acceptably, there are some downsides to their properties. However, these non-ideal characteristics of badminton rackets may be overcome with the usage of different manufacturing materials, specifically braided composites. An example of a braided material is KevlarⓇ. Kevlar is a heat resistant and high strength synthetic fibre that can be manufactured into braids using a maypole braiding system. These Kevlar braids can then be manipulated to a preferred shape for the curing process. In order to come up with a feasible design to base the prototype, a 3D modelling software (SolidWorksTM) is used. This ensures geometrical viability and possible to manufacture of the prototype. Modeling a badminton racket on Solidworks required the modelling of a racket head, and handle. The head was created using 2 ellipses, one of which acted as a skeleton, or mould for the Kevlar braid, and the other was a hollow ellipse which encompassed the mold and acted as the Kevlar braid. The solid ellipse was created in two halves, each having either an extrusion or a hole in the ends. This allowed them to easily attach to form a full ellipse. Once modeled, the solid ellipse was 3D printed to act as the curing mandrel, an internal skeleton for the Kevlar braids. In order to attach the head to the handle, a three-part connector piece was created and 3D printed. The rod of the racket was not created with an internal skeleton because the flexibility would falter. Instead, the Kevlar braids were slid off the material after curing and attached to the racket heads connector piece. In order to have a balanced weight ratio throughout the racket, the grip was created with an internal 3D printed skeleton. This structure allowed for a feasible, flexible, and strong Kevlar based product.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.015
Threshold uncertainty score0.051

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0150.005

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.263
Teacher spread0.242 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueAlberta Academic ReviewSame topic3D Shape Modeling and AnalysisFrench-language works237,207