MétaCan
Menu
← Back to cohort
Record W2982135546 · doi:10.1111/cid.12844

Failure analysis of high performance polymers and new generation cubic zirconia used for implant‐supported fixed, cantilevered prostheses

2019· article· en· W2982135546 on OpenAlexvenueno aff
Burak Yılmaz, Burcu Batak, Robert R. Seghi

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2019
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsMaterials sciencePeekCubic zirconiaCantileverBase (topology)Composite materialTitaniumCeramicComposite numberImplantPolymerMetallurgySurgeryMathematics

Abstract

fetched live from OpenAlex

BACKGROUND: The load-to-failure performance of computer-assisted design and computer-assisted manufacturing (CAD-CAM) high performance polymers (HPP) and new generation cubic zirconia (Zir) material when used with titanium (Ti) bases for implant-supported fixed prostheses with cantilevers is unknown. PURPOSE: To evaluate the load-to-failure performance of different CAD-CAM fabricated HPP and a new generation cubic Zir in a cantilevered situation when used with Ti bases. MATERIALS AND METHODS: Five specimens with a Ti base and five specimens without Ti bases were fabricated from seven different CAD-CAM HPPs (100% PEEK [J and CP], 80% PEEK with 20% filler [BRE], 80% PEKK with 20% filler [PK], ceramic reinforced PEEK [ZZ], interlaced fiberglass and resin [TR], fiber-composite material [T]). Five specimens with Ti base and two specimens without Ti base were prepared from a new generation cubic Zir (DD) and a 3Y-TZP Zir (FZR) as the control group (N = 84). All specimens (8 × 7 × 30 mm) were stabilized using a clamp attached to the first 20 mm of each specimen for a 10 mm cantilever. Static loading was applied vertically on the cantilever and the maximum load-to-failure values (N) were analyzed using a two-way ANOVA and t-test (alpha = .05). RESULTS: HPP and Zir specimens without Ti bases had significantly higher load-to-failure values than Ti based ones in all groups (P < .05). PK with Ti base had significantly lower load-to-failure values than other materials (P < .001). FZR showed significantly higher load-to-failure values than all HPPs and DD (P < .001). CONCLUSIONS: Load-to-failure values of HPPs and Zir were lower when Ti bases were used. New generation cubic Zir and all HPPs had lower load-to-failure values than FZR. HPPs performance varied among tested materials. PEKK with Ti base had the lowest load-to-failure value.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.112
GPT teacher head0.423
Teacher spread0.311 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→