S132 Ten-year efficacy and safety following bronchial thermoplasty for asthma – the BT10+ study

2019· article· en· W2983079491 on OpenAlexaff
Rekha Chaudhuri, A Rubin, Jussara Fiterman, Kaharu Sumino, J Lapa e Silva, Robert Niven, Salman Siddiqui, Karin Klooster, Pallav L. Shah, David Duhamel, Sumita Khatri, Richard G. Barbers, G. Mark Grubb, Michel Laviolette

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldSocial Sciences
TopicDelphi Technique in Research
Canadian institutionsUniversité Laval
Fundersnot available
KeywordsBronchial thermoplastyMedicineAsthmaBronchiectasisQuality of life (healthcare)Pulmonary function testingAdverse effectInternal medicinePediatricsLungAirway resistance

Abstract

fetched live from OpenAlex

Background Bronchial thermoplasty (BT) is a non-pharmacologic, endoscopic treatment for asthma not well controlled with long-acting b-agonists and inhaled corticosteroids. Long-term efficacy and safety of BT beyond 5 years is unknown. The BT10+ study was designed to evaluate the efficacy and safety of BT at 10+ years follow-up. Methods BT10+ is an international, multi-center, ≥10yrs follow-up study on subjects who were enrolled in the AIR, RISA and AIR2 BT trials. Demographics, quality of life, lung function, severe exacerbations (SE, defined as asthma exacerbations requiring systemic corticosteroids) and healthcare utilisation for the previous year were collected at the BT10+ study visit. Additionally, AIR2 subjects who received a pulmonary high-resolution CT (HRCT) at baseline had a second scan at the BT10+ study visit to determine if clinically relevant changes, such as bronchiectasis, occur after BT. Results Of 429 subjects enrolled AIR, RISA, and AIR2, 192 were followed-up at 10.6–15.8 years (12.1 median) post-treatment at 16 centers; of these, 136 were treated with BT and 38 were control/sham subjects in previous studies. Baseline characteristics between subjects enrolled and not enrolled in BT10+ did not show meaningful differences. For BT subjects, no increases in the rate of hospitalisations or ER visits were observed compared to baseline and rates of SE were stable compared to Year 1 (figure 1). While both groups experienced fewer SE after treatment, BT subjects had fewer SE than control/sham subjects at the BT10+ visit; this was not significant. Quality of life (AQLQ, ACQ) and spirometry results were comparable between Years 1, 5, and 10+ for both groups. Pulmonary HRCT scans from AIR2 subjects at the BT10+ study visit showed 9.5% (2/21) of control/sham subjects and 13.4% (13/97) of BT subjects had bronchiectasis; however, when these were compared with baseline HRCT scans, only 5.3% (5/94) of BT subjects had developed bronchiectasis after their baseline visit. Conclusion The BT10+ study suggests that efficacy of BT is sustained over 10 years and that BT has an acceptable safety profile.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.022

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.003
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.051
GPT teacher head0.408
Teacher spread0.357 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2019
Admission routes1
Has abstractyes

Explore more

Same topicDelphi Technique in ResearchFrench-language works237,207