MétaCan
Menu
Back to cohort
Record W2986532543 · doi:10.1088/1741-2552/ab5551

Feasibility of differentially measuring afferent and efferent neural activity with a single nerve cuff electrode

2019· article· en· W2986532543 on OpenAlexafffund
Parisa Sabetian, Paul B. Yoo

Bibliographic record

VenueJournal of Neural Engineering · 2019
Typearticle
Languageen
FieldNeuroscience
TopicNeuroscience and Neural Engineering
Canadian institutionsUniversity Health NetworkToronto Rehabilitation InstituteUniversity of Toronto
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsEfferentAfferentNeural activityNeuroscienceCuffElectrodeBiomedical engineeringComputer scienceMedicineChemistryPsychologySurgery

Abstract

fetched live from OpenAlex

OBJECTIVE: Advances in electrode technology have facilitated the development of neuroprostheses for restoring motor/sensory function in disabled individuals. Information extracted from a whole nerve, recorded using cuffs, can provide signals that control the operation of neuroprostheses. However, the amount of information that can be extracted from a tripolar cuff-which provides the highest signal-to-noise ratio (SNR)-is limited. The physical symmetry of the tripolar cuff results in neural recordings that cannot differentiate afferent versus efferent signals. In this study, we introduced a tetrapolar cuff to achieve low-noise and directionally sensitive recording. APPROACH: The tetrapolar cuff was initially designed using a computational approach. A finite element model was used to solve the electric potential generated at the electrode contacts by active electrical sources, such as the nodes of Ranvier and an artifact noise source. The resulting single fiber action potentials (SFAPs) and artifact noise signals (ANS) were used to characterize the performance of the tetrapolar configuration of the electrode length (EL) and electrode edge length (EEL) on simulated SFAP and ANS. The feasibility of using a tetrapolar cuff to differentiate afferent/efferent action potentials by applying potassium chloride in anesthetized rats was also investigated. MAIN RESULTS: Both the computational and experimental results of this study indicated that directional recording can be achieved using a tetrapolar cuff. Testing different design criteria (e.g. EL and EEL) showed that at EL values above 15 mm and EEL ⩾ 2 mm, the tetrapolar cuffs can yield larger SNRs than equally-sized tripolar cuffs. SIGNIFICANCE: This study indicated that low-noise directionally sensitive measurement of neural activity can be achieved with a tetrapolar cuff. The experimental results confirmed the feasibility of using a tetrapolar cuff to differentiate afferent/efferent signals by applying potassium chloride. Further work is needed to determine whether the tetrapolar cuff can differentiate afferent/efferent physiologically elicited neural activities.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.089
Threshold uncertainty score0.953

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.237
Teacher spread0.199 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Neural EngineeringSame topicNeuroscience and Neural EngineeringFrench-language works237,207