MétaCan
Menu
Back to cohort
Record W2989269490 · doi:10.1089/dia.2019.0356

Safety and Effectiveness of an Investigational Insulin Delivery Device Providing Basal/Bolus Therapy with Rapid-Acting or Regular Human Insulin in Adults with Type 2 Diabetes

2019· article· en· W2989269490 on OpenAlexaff
Ronnie Aronson, Edward T. Mahoney, Drilon Saliu, David Sze, Didier Morel, Leya Bergquist, Laurence Hirsch

Bibliographic record

VenueDiabetes Technology & Therapeutics · 2019
Typearticle
Languageen
FieldMedicine
TopicDiabetes Management and Research
Canadian institutionsLMC Diabetes & Endocrinology (Canada)
FundersBD
KeywordsMedicineGlycemicInsulinInsulin lisproType 2 diabetesType 1 diabetesDiabetes mellitusGlycated hemoglobinBolus (digestion)Internal medicineRegular insulinGastroenterologyEndocrinologyHypoglycemia

Abstract

fetched live from OpenAlex

Background: This study undertook to assess usability, 24-h glycemic profiles, and safety of an investigational basal/bolus insulin delivery device (IDD) providing rapid-acting or regular human insulin (RHI) for people with type 2 diabetes (T2D) transitioning from multiple daily insulin injections (MDIs). Methods: This prospective, single-center, open-label two-period study enrolled adults with T2D and glycated hemoglobin (HbA1c) 7%–11% (53–97 mmol/M). Participants continued the usual MDI therapy during a 2- to 3-day in-clinic MDI period and then within 7 days were switched to the IDD, using current insulin dose, for a 6-day in-clinic IDD period, with blinded continuous glucose monitoring throughout the in-clinic periods. Results: We enrolled 21 participants (mean ± standard deviation age 57 ± 8 years; HbA1c 8.2% ± 0.9% [66 ± 9.8 mmol/M]) using U-100 insulin lispro ( n = 11) or who switched to U-100 RHI ( n = 10). Glycemic measures improved from the MDI to IDD period, including fasting blood glucose (BG), 141.2 ± 38.3 mg/dL (7.8 ± 2.1 mmol/L) versus 121.2 ± 35.0 mg/dL (6.7 ± 1.9 mmol/L; P = 0.002), respectively; 24-h mean BG, 137.0 ± 20.5 mg/dL (7.6 ± 1.1 mmol/L) versus 125.0 ± 16.5 mg/dL (6.9 ± 0.9 mmol/L; P = 0.004); and time in range (at 70–180 mg/dL; 3.9–10 mmol/L), 81.0% ± 14.4% versus 87.5% ± 10.6% ( P = 0.008). No significant differences between MDIs and IDD use were recorded for time <70 mg/dL (1.6% ± 2.7% vs. 3.1% ± 2.7%, P = 0.08), CV%, or mean of daily differences. Mean amplitude of glycemic excursions was significantly lower with the IDD ( P = 0.011). There were no significant differences between insulin lispro and RHI for any glycemic measure. No serious adverse events were recorded. Conclusions: In the context of this exploratory study, the IDD was safe and effective to administer insulin lispro and RHI for adults with T2D.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.279
Threshold uncertainty score0.895

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.272
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueDiabetes Technology & TherapeuticsSame topicDiabetes Management and ResearchFrench-language works237,207