MétaCan
Menu
Back to cohort
Record W2990119101 · doi:10.1152/ajpregu.00212.2019

Near-infrared diffuse correlation spectroscopy tracks changes in oxygen delivery and utilization during exercise with and without isolated arterial compression

2019· article· en· W2990119101 on OpenAlexaff
Wesley J. Tucker, Ryan Rosenberry, Darian Trojacek, Belinda Sanchez, Robert F. Bentley, Mark J. Haykowsky, Fenghua Tian, Michael D. Nelson

Bibliographic record

VenueAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology · 2019
Typearticle
Languageen
FieldMedicine
TopicCardiovascular and exercise physiology
Canadian institutionsUniversity of Toronto
FundersNational Heart, Lung, and Blood InstituteNational Institutes of HealthAmerican Heart Association
KeywordsOxygenBlood flowCardiologyBrachial arteryMedicineInternal medicineRadial arteryOxygen saturationArteryMyoglobinChemistryBlood pressureBiochemistry

Abstract

fetched live from OpenAlex

Near-infrared diffuse correlation spectroscopy (NIR-DCS) is an emerging technology for simultaneous measurement of skeletal muscle microvascular oxygen delivery and utilization during exercise. The extent to which NIR-DCS can track acute changes in oxygen delivery and utilization has not yet been fully established. To address this knowledge gap, 14 healthy men performed rhythmic handgrip exercise at 30% maximal voluntary contraction, with and without isolated brachial artery compression, designed to acutely reduce convective oxygen delivery to the exercising muscle. Radial artery blood flow (Duplex Ultrasound) and NIR-DCS derived variables [blood flow index (BFI), tissue oxygen saturation ([Formula: see text]), and metabolic rate of oxygen ([Formula: see text])] were simultaneously measured. During exercise, both radial artery blood flow (+51.6 ± 20.3 mL/min) and DCS-derived BFI (+155.0 ± 82.2%) increased significantly ( P < 0.001), whereas [Formula: see text] decreased −7.9 ± 6.2% ( P = 0.002) from rest. Brachial artery compression during exercise caused a significant reduction in both radial artery blood flow (−32.0 ± 19.5 mL/min, P = 0.001) and DCS-derived BFI (−57.3 ± 51.1%, P = 0.01) and a further reduction of [Formula: see text] (−5.6 ± 3.8%, P = 0.001) compared with exercise without compression. [Formula: see text] was not significantly reduced during arterial compression ( P = 0.83) due to compensatory reductions in [Formula: see text], driven by increases in deoxyhemoglobin/myoglobin (+7.1 ± 6.1 μM, P = 0.01; an index of oxygen extraction). Together, these proof-of-concept data help to further validate NIR-DCS as an effective tool to assess the determinants of skeletal muscle oxygen consumption at the level of the microvasculature during exercise.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.939
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.261
Teacher spread0.248 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueAmerican Journal of Physiology-Regulatory, Integrative and Comparative PhysiologySame topicCardiovascular and exercise physiologyFrench-language works237,207