MétaCan
Menu
Back to cohort
Record W2991223206 · doi:10.1097/mat.0000000000001082

Association Between Neurohormone Levels and Exercise Testing Measures in Patients with Mechanical Circulatory Supports

2019· article· en· W2991223206 on OpenAlexaff
Liza Grosman‐Rimon, Erez Kachel, Michael McDonald, Spencer D. Lalonde, Paul S. F. Yip, Roberto Vanin Pinto Ribeiro, M. Adamson, David Z. Cherney, Vivek Rao

Bibliographic record

VenueASAIO Journal · 2019
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsUniversity of TorontoUniversity Health Network
Fundersnot available
KeywordsChronotropicOxygen pulseInternal medicineMedicineCardiologyAnaerobic exerciseRespiratory minute volumeVO2 maxStroke volumeRespiratory exchange ratioHeart rateNorepinephrineCardiac outputHemodynamicsEndocrinologyBlood pressureRespiratory systemPhysical therapy

Abstract

fetched live from OpenAlex

Continuous-flow left ventricular assist device (CF-LVAD) recipients exhibit impaired exercise capacity. Long-term continuous blood flow also elevates norepinephrine (NE) and aldosterone (Aldo) levels. However, the relationship between exercise capacity and neurohormonal activation has not been elucidated. Our study objective was to assess the association between cardiopulmonary exercise testing (CPT) measures and neurohormonal levels in CF-LVAD recipients. Symptom-limited CPT on a treadmill, using the modified Bruce protocol was performed in 15 CF-LVAD recipients. Norepinephrine and Aldo levels were measured, and the association between their levels and CPT measures were assessed. Peak VO2 (13.6 ml/kg/min) and percent age, sex predicted VO2 max (49.4%), and oxygen pulse (O2 pulse) (9.0 ± 4.0 ml/beat) were low, whereas minute ventilation/carbon dioxide output (VE/VCO2) slope (35) was elevated. In addition, VO2 at anaerobic threshold (VO2 AT), and O2 pulse values negatively correlated with NE levels. Norepinephrine levels positively correlated with chronotropic responses and heart rate (HR) recovery. Aldo levels in CF-LVAD recipients were not related to any CPT measures. Continuous-flow left ventricular assist device recipients exhibited impaired exercise capacity and chronotropic incompetence (CI). Despite the association of NE levels with chronotropic responses at peak exercise, neither NE levels nor chronotropic responses predicted peak VO2. This suggests that CI may not be the primary factor responsible for the low peak VO2. O2 pulse, which is a combined measure for stroke volume and peripheral oxygen extraction during exercise, was an independent predictor of peak VO2. Future studies should examine the contribution of peripheral factors to exercise capacity limitations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.200
Teacher spread0.183 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueASAIO JournalSame topicMechanical Circulatory Support DevicesFrench-language works237,207