MétaCan
Menu
Back to cohort
Record W2995496354 · doi:10.1115/1.4045661

Cartilage Biomechanical Response Differs Under Physiological Biaxial Loads and Uniaxial Cyclic Compression

2019· article· en· W2995496354 on OpenAlexafffund
Ali Shegaf, Andrew Speirs

Bibliographic record

VenueJournal of Biomechanical Engineering · 2019
Typearticle
Languageen
FieldMedicine
TopicOsteoarthritis Treatment and Mechanisms
Canadian institutionsCarleton University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsMaterials scienceCompression (physics)CartilageLubricationComposite materialBiomedical engineeringContact mechanicsFluid pressureConsolidation (business)Finite element methodStructural engineeringMechanicsAnatomyEngineering

Abstract

fetched live from OpenAlex

The main function of articular cartilage is to distribute loads and provide low friction for the opposing surfaces in synovial joints. Biphasic lubrication provided by high fluid load support due to relative motion of the contact surfaces has been widely accepted as the main lubrication mode in diarthrodial joints. However, assessment of chondrocyte response to mechanical loads typically employed nonphysiological uniaxial loads with static contact area. This study aimed to introduce a more physiologically relevant loading protocol for in vitro mechanobiological testing of cartilage explants. Finite element analysis was conducted to examine the biomechanical response of cartilage to two different loading regimes, biaxial loading, that permits migrating contact area, and unconfined uniaxial cyclic compression, traditionally used in mechanobiological experiments. Results predicted in this study showed that continuous tissue rehydration provided by relative surface motion maintained constant fluid pressure and tissue strains through the simulation. On the contrary, due to rapid tissue consolidation predicted in cyclic compression simulation, fluid pressure and transverse strain were reduced by 19% and 26%, respectively. Furthermore, relative surface motion simulation resulted in depth-dependent distribution of fluid pressure and tissue strains while unconfined uniaxial cyclic compression produced nearly uniform fluid pressure through the depth but higher at the center of the sample. Based on the results obtained from this study and since sliding contact occurs in vivo, this physiological loading mode should be considered in assessing biomechanical and mechanobiological cartilage behavior.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.043
Threshold uncertainty score0.833

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.246
Teacher spread0.232 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Biomechanical EngineeringSame topicOsteoarthritis Treatment and MechanismsFrench-language works237,207