MétaCan
Menu
Back to cohort
Record W2996082632 · doi:10.1002/mp.13959

A novel <sup>169</sup>Yb‐based dynamic‐shield intensity modulated brachytherapy delivery system for prostate cancer

2019· article· en· W2996082632 on OpenAlexafffund
Gabriel Famulari, Marie Duclos, Shirin A. Enger

Bibliographic record

VenueMedical Physics · 2019
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsMcGill University Health CentreMcGill University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsBrachytherapyNuclear medicineCollimated lightDosimetryMedicineRadiation therapyPhysicsRadiologyOptics

Abstract

fetched live from OpenAlex

Purpose Intensity modulated brachytherapy (IMBT) is a novel high dose rate brachytherapy (HDR BT) technique which incorporates static or dynamic shielding to increase tumor coverage and/or spare healthy tissues. The purpose of this study is to present a novel delivery system (AIM‐Brachy) design that can enable dynamic‐shield IMBT for prostate cancer. Methods The AIM‐Brachy system dynamically controls the rotation of platinum shields, placed within interstitial catheters, which partially collimate the radiation emitted from an 169 Yb source. Conventional HDR BT (10 Ci 192 Ir) and IMBT (18 Ci 169 Yb) plans were generated for 12 patients using an in‐house column generation‐based optimizer, coupled to a Geant4‐based dose calculation engine, RapidBrachyMC. Treatment plans were normalized to match the same PTV D 90 coverage as the clinical plan. Intershield attenuation effects were taken into account. A sensitivity analysis was performed to evaluate the dosimetric impact of systematic longitudinal source positioning errors ( 1 mm, 2 mm, and 3 mm) and rotational errors ( 5 , 10 and 15 ) on clinically relevant parameters (PTV D 90 and urethra D 10 ). Results The platinum shield reduced the dose rate on the shielded side at 1 cm to 18.1% of the dose rate on the unshielded side. For equal PTV D 90 coverage, the urethral D 10 was reduced by 13.3% 4.7%, without change to other plan quality indices (PTV V 100 , V 150, V 200 , bladder V 75 , rectum V 75 , HI, COIN). Delivery times for HDR BT and IMBT were 9.2 ± 1.6 min and 18.6 ± 4.0 min, respectively. In general, the PTV D 90 was more sensitive to source positioning errors than rotational errors, while the urethral D 10 was more sensitive to rotational errors than source positioning errors. For a typical range of positioning errors ( 1 mm, 5 ), the overall tolerance was &lt;2%. Conclusions The AIM‐Brachy system was proposed to deliver dynamic‐shield IMBT for prostate cancer with the potential to create a low dose tunnel within the urethra. The urethra‐sparing properties are desirable to minimize the occurrence and severity of urethral strictures or, alternatively, to provide a method for dose escalation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.929
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.267
Teacher spread0.259 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2019
Admission routes2
Has abstractyes

Explore more