MétaCan
Menu
Back to cohort
Record W2999507348 · doi:10.1002/jmri.27056

MRI vs. CT for the Detection of Liver Metastases in Patients With Pancreatic Carcinoma: A Comparative Diagnostic Test Accuracy Systematic Review and Meta‐Analysis

2020· review· en· W2999507348 on OpenAlexaff
Mostafa Alabousi, Matthew D. F. McInnes, Jean‐Paul Salameh, Janakan Satkunasingham, Yoan K. Kagoma, Leyo Ruo, Brandon M. Meyers, Tariq Aziz, Christian B. van der Pol

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2020
Typereview
Languageen
FieldMedicine
TopicPancreatic and Hepatic Oncology Research
Canadian institutionsJuravinski Cancer CentreHamilton Health SciencesOttawa Public HealthOttawa HospitalJuravinski HospitalMcMaster UniversityUniversity of Ottawa
Fundersnot available
KeywordsMedicineMeta-analysisPancreatic cancerMagnetic resonance imagingRadiologyConfidence intervalPancreasDiagnostic accuracyCancerNuclear medicineInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: The detection of liver metastases is important for pancreatic cancer curative treatment eligibility. The data suggest that magnetic resonance imaging (MRI) is more sensitive than computed tomography (CT) for the diagnosis of pancreatic cancer liver metastases. However, MRI is not currently recommended in multiple published guidelines. PURPOSE: To perform a comparative diagnostic test accuracy systematic review and meta-analysis comparing CT and MRI for pancreatic cancer liver metastases detection. STUDY TYPE: Systematic review and meta-analysis. DATA SOURCES: MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, Scopus, and multiple radiology society meeting archives were searched until November 2018. Comparative design studies reporting on liver CT and MRI accuracy for detection of pancreatic cancer liver metastases in the same cohort were included. FIELD STRENGTH: 1.5T or 3.0T. ASSESSMENT: Demographic, methodologic, and diagnostic test accuracy data were extracted. Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool. STATISTICAL TESTS: Accuracy metrics were obtained using bivariate random-effects meta-analysis. The impact of different covariates on accuracy estimates was assessed using a meta-regression model. Covariates included modality, study design, tumor characteristics, risk of bias, and imaging protocols. RESULTS: Fourteen studies including 987 patients with pancreatic cancer (205 with liver metastases) were included. Sensitivity for CT and MRI was 45% (confidence intervals [95% CI] 21-71%) and 83% (95% CI 74-88%), respectively. Specificity for CT and MRI was 94% (95% CI 84-98%) and 96% (95% CI 93-97%), respectively. The greater observed sensitivity of MRI was preserved in the meta-regression model (P = 0.01), while no difference in specificity was detected (P = 0.16). CT sensitivity was highest for triphasic and quadriphasic examinations compared to single phase or biphasic protocols (P = 0.03). Most studies were at high risk of bias. DATA CONCLUSION: MRI is more sensitive than CT for pancreatic cancer liver metastases detection, accounting for confounding variables. Consideration of this finding in clinical practice guidelines is recommended. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 3.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.033
metaresearch head score (Gemma)0.096
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.033
Threshold uncertainty score0.177

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0330.096
Meta-epidemiology (narrow)0.0030.002
Meta-epidemiology (broad)0.0190.049
Bibliometrics0.0080.009
Science and technology studies0.0010.001
Scholarly communication0.0040.003
Open science0.0030.002
Research integrity0.0030.003
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.054
GPT teacher head0.358
Teacher spread0.304 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations65
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicPancreatic and Hepatic Oncology ResearchFrench-language works237,207