MétaCan
Menu
Back to cohort
Record W3001246089 · doi:10.22374/jded.v3i1.25

Efficacy of Self-Administration of a Personal Mechanical Eyelid Device for the Treatment of Dry Eye Disease, Blepharitis and Meibomian Gland Disease

2020· article· en· W3001246089 on OpenAlexvenueno aff
David J. Schanzlin, John Olkowski, John Coble, Wendy Gross, Michael Dash

Bibliographic record

VenueJournal of Dry Eye Disease · 2020
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsnot available
Fundersnot available
KeywordsMeibomian glandBlepharitisMedicineEyelidOphthalmologyArtificial tearsDermatology

Abstract

fetched live from OpenAlex

PurposeA prospective study to evaluate the safety and efficacy of a novel mechanical eyelid device (NuLidsTM by NuSight Medical, LLC, Rancho Santa Fe, CA) used at home for the treatment of dry eye disease (DED), blepharitis (anterior and posterior) and meibomian gland disease (MGD).
 MethodsSeventy-four (74) eyes of thirty-seven (37) patients were self-treated with the NuLidsTM device at home. Inclusion criteria included blepharitis, MGD and/or DED. After an initial training session, each eyelid was treated for 15 seconds (total of 1 minute per treatment session per day). The following tests were collected before the first treatment and after the final treatment: OSDI survey, BCVA, Tear Osmolarity Test (Tear Lab), Tear Break Up Time (TBUT), Meibomian Gland Score (MGS), Meibomian Glands Yielding Liquid Secre-tions (MGYLS), Sicca Ocular Staining Score. Satisfaction with treatment survey was taken after treatment.
 ResultsAll measured parameters had a statistically significant improvement. Symptoms improved based on an average decrease in OSDI score from 54.2 ± 19.5 (mean ± SD) to 26.7 ± 18.4 (P < 0.001). Tear osmolarity improved from 315 ± 15.7 to 306 ± 13.9 (P = 0.002). TBUT was noted to improve from pre-treatment of 4.8 ± 1.7 seconds to post-treatment of 7.9 ± 4.1 seconds (P < 0.001). MGS improved from 8.9 ± 5.1 to 7.0 ± 5.9 (P = 0.01). MGYLS improved from 8.7 ± 6.2 to 15.8 ± 6.9 (P = 0.002). Sicca Ocular Staining Score improved from 2.7 ± 2.1 to 1.4 ± 1.5 (P = 0.002).There were no adverse events. No corneal or conjunctival trauma. No patients dropped out of the trial due to discomfort. 91% of participants agreed or strongly agreed that the device was easy and convenient to use. Of those previously using manual lid scrubs, 82% felt the NuLids device was easier and more comfortable to use. 89% described little or no discomfort. 95% were satisfied or very satisfied with the overall treatment.
 ConclusionsA mechanical device was safely used by patients at home for 1 minute daily for 30 days to treat DED, blepharitis, and MGD. There was a statistically significant improvement in signs and symptoms of DED as shown by improved OSDI, tear osmolarity, TBUT, MGS, MGYLS, and Ocular Staining Score. High patient satisfaction along with the low risk of adverse events supports the use of this device as a valid tool to treat DED, blepharitis, and MGD.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.019
Threshold uncertainty score0.569

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.294
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Dry Eye DiseaseSame topicOcular Surface and Contact LensFrench-language works237,207