MétaCan
Menu
Back to cohort

Evaluation of contrast sensitivity in patients with advanced glaucoma: comparison of two tests

2020· article· en· W3001251370 on OpenAlexaff
Alessandro A. Jammal, Bruna Gil Ferreira, Camila Zangalli, Jayme R Vianna, Atalie C. Thompson, Paul H. Artes, Vital Paulino Costa, Alexandre Soares Castro Reis

Bibliographic record

VenueBritish Journal of Ophthalmology · 2020
Typearticle
Languageen
FieldMedicine
TopicOphthalmology and Visual Impairment Studies
Canadian institutionsDalhousie University
FundersCoordenação de Aperfeiçoamento de Pessoal de Nível SuperiorFight for Sight UK
KeywordsMedicineVisual fieldGlaucomaVisual acuityContrast (vision)OphthalmologyRepeatabilityChartIntraocular pressureAbsolute deviationOptometryMathematicsStatisticsOptics

Abstract

fetched live from OpenAlex

Aims To evaluate contrast sensitivity (CS) in patients with advanced glaucomatous visual field damage, and to compare two clinical CS tests. Methods This was a cross-sectional test–retest study. Twenty-eight patients with open-angle glaucoma, visual acuity (VA) better than 20/40 and visual field mean deviation (MD) worse than −15 dB were enrolled. Patients underwent VA, visual field and CS testing with the Pelli-Robson (PR) chart and the Freiburg Visual Acuity and Contrast Test (FrACT). Retest measurements were obtained within 1 week to 1 month. Results Median (IQR) age and MD were 61.5 (55.5 to 69.2) years and −27.7 (−29.7 to −22.7) dB, respectively. Median (IQR) VA was 0.08 logarithm minimum angle of resolution (0.02 to 0.16), corresponding to 20/25 (20/20 to 20/30). Median (IQR) CS was 1.35 (1.11 to 1.51) log units with the PR chart and 1.39 (1.24 to 1.64) log units with FrACT. VA explained less than 40% of the variance in CS (adjusted R2=0.36). CS estimates of both tests were closely related (rho=0.88, p=0.001), but CS was 0.09 log units higher with FrACT compared with the PR chart, and the 95% repeatability intervals (Bland-Altman) were 46% tighter with the PR chart. Conclusions Despite near-normal VA, almost all patients showed moderate to profound deficits in CS. CS measurement provides additional information on central visual function in patients with advanced glaucoma.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.007
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.007
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.052
GPT teacher head0.384
Teacher spread0.332 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueBritish Journal of OphthalmologySame topicOphthalmology and Visual Impairment StudiesFrench-language works237,207