MétaCan
Menu
Back to cohort

Preclinical Validation of a Single-Scan Rest/Stress Imaging Technique for <sup>13</sup> N-Ammonia Positron Emission Tomography Cardiac Perfusion Studies

2020· article· en· W3001785105 on OpenAlexaff
Nicolas J. Guehl, Matthieu Pelletier‐Galarneau, Dustin Wooten, Jorge Guerrero, Aurélie Kas, Marc D. Normandin, Georges El Fakhri, Nathaniel M. Alpert

Bibliographic record

VenueCirculation Cardiovascular Imaging · 2020
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsOttawa HospitalMontreal Heart Institute
FundersNational Institute of Biomedical Imaging and BioengineeringNational Heart, Lung, and Blood Institute
KeywordsPositron emission tomographyNuclear medicineMyocardial perfusion imagingPerfusionPositron emissionTomographyPositronPreclinical imagingMedicineRadiologyPhysicsNuclear physicsIn vivo

Abstract

fetched live from OpenAlex

Background: We previously proposed a technique for quantitative measurement of rest and stress absolute myocardial blood flow (MBF) using a 2-injection single-scan imaging session. Recently, we validated the method in a pig model for the long-lived radiotracer 18 F-Flurpiridaz with adenosine as a pharmacological stressor. The aim of the present work is to validate our technique for 13 NH 3 . Methods: Nine studies were performed in 6 pigs; 5 studies were done in the native state and 4 after infarction of the left anterior descending artery. Each study consisted of 3 dynamic scans: a 2-injection rest-rest single-scan acquisition (scan A), a 2-injection rest/stress single-scan acquisition (scan B), and a conventional 1-injection stress acquisition (scan C). Variable doses of adenosine combined with dobutamine were administered to induce a wide range of MBF. The 2-injection single-scan measurements were fitted with our nonstationary kinetic model (MGH2). In 4 studies, 13 NH 3 injections were paired with microsphere injections. MBF estimates obtained with our method were compared with those obtained with the standard method and with microspheres. We used a model-based method to generate separate rest and stress perfusion images. Results: In the absence of stress (scan A), the MBF values estimated by MGH2 were nearly the same for the 2-radiotracer injections (mean difference: 0.067±0.070 mL·min −1 ·cc −1 , limits of agreement: [−0.070 to 0.204] mL·min −1 ·cc −1 ), showing good repeatability. Bland-Altman analyses demonstrated very good agreement with the conventional method for both rest (mean difference: −0.034±0.035 mL·min −1 ·cc −1 , limits of agreement: [−0.103 to 0.035] mL·min −1 ·cc −1 ) and stress (mean difference: 0.057±0.361 mL·min −1 ·cc −1 , limits of agreement: [−0.651 to 0.765] mL·min −1 ·cc −1 ) MBF measurements. Positron emission tomography and microsphere MBF measurements correlated closely. Very good quality perfusion images were obtained. Conclusions: This study provides in vivo validation of our single-scan rest-stress method for 13 NH 3 measurements. The 13 NH 3 rest/stress myocardial perfusion imaging procedure can be compressed into a single positron emission tomography scan session lasting less than 15 minutes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.480
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.304
Teacher spread0.268 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueCirculation Cardiovascular ImagingSame topicCardiac Imaging and DiagnosticsFrench-language works237,207