MétaCan
Menu
Back to cohort
Record W3001977236 · doi:10.1088/1361-6579/ab6f53

The repeatability of estimated systolic time intervals in healthy subjects using seismocardiogram and electrocardiogram

2020· article· en· W3001977236 on OpenAlexaff
Vahid Zakeri, Kouhyar Tavakolian, Andrew P. Blaber, Erwin Bauer, Parastoo Dehkordi, Farzad Khosrow-Khavar

Bibliographic record

VenuePhysiological Measurement · 2020
Typearticle
Languageen
FieldEngineering
TopicNon-Invasive Vital Sign Monitoring
Canadian institutionsUniversity of British ColumbiaSimon Fraser University
Fundersnot available
KeywordsRepeatabilityMedicineHeart rateImpedance cardiographyCardiologyVentricleElectrocardiographyInternal medicineMathematicsStatisticsBlood pressureStroke volume

Abstract

fetched live from OpenAlex

OBJECTIVE: We investigated the repeatability of systolic time intervals (STIs) in healthy subjects using a combination of seismocardiogram (SCG) and electrocardiogram (ECG). STIs have been extensively used in the past to quantify heart performance, particularly the left ventricle. In this study, STIs included pre-ejection period (PEP), left ventricular ejection time (LVET), and their ratio. APPROACH: We conducted the repeatability test of STI estimation through two experiments. The first involved three consecutive one-minute recordings separated by one-minute intervals, and the second involved two one-minute recordings separated by 24 h. Twenty healthy subjects participated in our study. We considered the coefficient of variation (CV) to quantify the repeatability. As there was no agreed upon values for optimal CV values, we compared our results with an alternative method using a combination of impedance cardiography (ICG) and ECG. Similar to our method, the alternative method was noninvasive and could be employed for personal heart monitoring. We also studied the repeatability after STIs were corrected for heart rate using two approaches. The first approach used a multiplicative factor per subject based on the heart rates in each recordings of that subject. The second approach employed sex-specific regression models for all subjects (Weissler's equations). MAIN RESULTS: We found that the repeatability of our method (SCG and ECG) was in agreement with the alternative method (ICG and ECG) in both experiments. Moreover, the Weissler's equations approach for heart rate increased the repeatability. SIGNIFICANCE: It can be concluded that estimation of PEP, LVET and their ratio through SCG and ECG signals was repeatable in healthy subjects.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.010
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.093
GPT teacher head0.272
Teacher spread0.179 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2020
Admission routes1
Has abstractyes

Explore more

Same venuePhysiological MeasurementSame topicNon-Invasive Vital Sign MonitoringFrench-language works237,207