MétaCan
Menu
Back to cohort
Record W3002810258 · doi:10.3389/fphys.2019.01598

Intermittent Calf Compression Delays the Onset of Presyncope in Young Healthy Individuals

2020· article· en· W3002810258 on OpenAlexafffund
Brooke C. D. Hockin, Victoria E. Claydon

Bibliographic record

VenueFrontiers in Physiology · 2020
Typearticle
Languageen
FieldMedicine
TopicCardiovascular Syncope and Autonomic Disorders
Canadian institutionsInternational Collaboration On Repair DiscoveriesSimon Fraser UniversityUniversity of British Columbia
FundersCanadian Institutes of Health Research
KeywordsPresyncopeMedicineOrthostatic vital signsAnesthesiaOrthostatic intoleranceCardiologyTranscranial DopplerBlood pressureCerebral autoregulationHeart rateMidodrineInternal medicineTilt table testAutoregulation

Abstract

fetched live from OpenAlex

Orthostatic fluid shifts reduce the effective circulating volume and thus contribute to syncope susceptibility. Recurrent syncope has a devastating impact on quality of life and is challenging to manage effectively. To blunt orthostatic fluid shifts, static calf compression garments are often prescribed to patients with syncope, but have questionable efficacy. Intermittent calf compression, which mimics the skeletal muscle pump to minimize pooling and filtration, holds promise for the management of syncope. We aimed to evaluate the effectiveness of intermittent calf compression for increasing orthostatic tolerance (OT; time to presyncope). We conducted a randomized single-blind crossover study, in which participants (n=21) underwent three graded, 60° head-up-tilt tests to presyncope with combined lower body negative pressure on separate days. Low frequency intermittent calf compression (ICLF; 4s on and 11s off) at 0-30mmHg and 0-60mmHg was applied during two tests and compared to a placebo condition where the garment was fitted, but no compression applied. We measured continuous leg circumference changes (strain gauge plethysmography), cardiovascular responses (finger plethysmography; Finometer Pro), end tidal gases (nasal cannula), and cerebral blood flow velocity (CBFv, transcranial Doppler). The 0-60mmHg ICLF increased OT (33±2.2min) compared to both placebo (26±2.4min; p<0.001) and 0-30mmHg ICLF (25±2.7min; p<0.001). Throughout testing 0-60mmHg ICLF reduced orthostatic fluid shifts compared to both placebo and 0-30mmHg ICLF (p<0.001), with an associated improvement in stroke volume (p<0.001), allowing blood pressure to be maintained at a reduced heart rate (p<0.001). In addition, CBFv was higher with 0-60mmHg ICLF than 0-30mmHg ICLF and placebo (p<0.001). Intermittent calf compression is a promising novel intervention for the management of orthostatic intolerance, which may provide affected individuals renewed independence and improved quality of life.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.214
Threshold uncertainty score0.359

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.254
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueFrontiers in PhysiologySame topicCardiovascular Syncope and Autonomic DisordersFrench-language works237,207