Periprosthetic fracture fixation in Vancouver B1 femoral shaft fractures: A biomechanical study comparing two plate systems
Bibliographic record
Abstract
INTRODUCTION: Periprosthetic fractures of the femur are an increasing problem in today's trauma and orthopaedic surgery. Owing to the hip stem, implant anchorage is very difficult in the proximal femur. This study compares two plate systems regarding their biomechanical properties and the handling in periprosthetic fracture fixation of the proximal femur. MATERIALS AND METHODS: Using eight pairs of fresh, frozen human proximal femora the Locking Compression Plate/Locking Attachment Plate construct (LCP/LAP) (group I, DePuy Synthes) was compared to the new LOQTEQ® periprosthetic distal lateral femur plate (group II, AAP Implantate AG). After implantation of press fit femoral hip stems a Vancouver B1 fracture model was used. Biomechanical testing was performed by cyclic axial loading with a constant increment of 0.1 N/cycle starting from 750 N axial loading. Every 250 cycles an a.p. x-ray was done to evaluate failure. RESULTS: The Group II showed significant higher axial stiffness (+42%) compared with Group I. In addition, Group II withstood significantly more load-cycles until failure (20%). The mode of catastrophic failure was plate breakage in Group II, whereas, in Group I, all plates showed an early bending followed by plate breakage. DISCUSSION AND CONCLUSION: Both plate systems enable screw placement around hip stems. The hinge plate showed superior biomechanical results compared with the locking compression plate/locking attachment plate construct. Furthermore, the hinge plate offers variable hinges and variable angel locking making bicortical screw placement around hip stems more comfortable and safe. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: The results of this study can be directly transferred to patient care. With the innovative hinge plate, the surgeon has a biomechanically superior implant, which also offers improved options for screw placement compared to a standard locking plate.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".