MétaCan
Menu
Back to cohort
Record W3004479972 · doi:10.1016/j.jot.2020.01.005

Periprosthetic fracture fixation in Vancouver B1 femoral shaft fractures: A biomechanical study comparing two plate systems

2020· article· en· W3004479972 on OpenAlexaboutno aff
Dirk Wähnert, Marcus Müller, Hendrik B. Tiedemann, Sven Märdian, Michael J. Raschke, Clemens Kösters

Bibliographic record

VenueJournal of Orthopaedic Translation · 2020
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsPeriprostheticFemurFixation (population genetics)OrthodonticsHingeMedicineImplantCompression (physics)Orthopedic surgeryBreakageStiffnessBiomechanicsSurgeryMaterials scienceArthroplastyStructural engineeringAnatomyComposite materialEngineering

Abstract

fetched live from OpenAlex

INTRODUCTION: Periprosthetic fractures of the femur are an increasing problem in today's trauma and orthopaedic surgery. Owing to the hip stem, implant anchorage is very difficult in the proximal femur. This study compares two plate systems regarding their biomechanical properties and the handling in periprosthetic fracture fixation of the proximal femur. MATERIALS AND METHODS: Using eight pairs of fresh, frozen human proximal femora the Locking Compression Plate/Locking Attachment Plate construct (LCP/LAP) (group I, DePuy Synthes) was compared to the new LOQTEQ® periprosthetic distal lateral femur plate (group II, AAP Implantate AG). After implantation of press fit femoral hip stems a Vancouver B1 fracture model was used. Biomechanical testing was performed by cyclic axial loading with a constant increment of 0.1 N/cycle starting from 750 N axial loading. Every 250 cycles an a.p. x-ray was done to evaluate failure. RESULTS: The Group II showed significant higher axial stiffness (+42%) compared with Group I. In addition, Group II withstood significantly more load-cycles until failure (20%). The mode of catastrophic failure was plate breakage in Group II, whereas, in Group I, all plates showed an early bending followed by plate breakage. DISCUSSION AND CONCLUSION: Both plate systems enable screw placement around hip stems. The hinge plate showed superior biomechanical results compared with the locking compression plate/locking attachment plate construct. Furthermore, the hinge plate offers variable hinges and variable angel locking making bicortical screw placement around hip stems more comfortable and safe. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: The results of this study can be directly transferred to patient care. With the innovative hinge plate, the surgeon has a biomechanically superior implant, which also offers improved options for screw placement compared to a standard locking plate.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.164
Threshold uncertainty score0.750

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.307
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Orthopaedic TranslationSame topicOrthopaedic implants and arthroplastyFrench-language works237,207