MétaCan
Menu
Back to cohort

Keeping older individuals cool in hot and moderately humid conditions: wetted clothing with and without an electric fan

2020· article· en· W3005202533 on OpenAlexfundno aff
Matthew N. Cramer, Mu Huang, Gilbert Moralez, Craig G. Crandall

Bibliographic record

VenueJournal of Applied Physiology · 2020
Typearticle
Languageen
FieldEnvironmental Science
TopicClimate Change and Health Impacts
Canadian institutionsnot available
FundersNational Institutes of HealthNational Institute of General Medical SciencesNatural Sciences and Engineering Research Council of CanadaGovernment of CanadaU.S. Department of Defense
KeywordsRelative humidityTap waterAnimal scienceHeart rateBlood pressureMedicineEnvironmental scienceEnvironmental engineeringMeteorologyBiologyInternal medicine

Abstract

fetched live from OpenAlex

The present study evaluated whether wearing a water-soaked t-shirt, with or without electric fan use, mitigates thermal and cardiovascular strain in older individuals exposed to hot and moderately humid conditions. Nine healthy older individuals (68 ± 4 yr; five women) completed three 120-min heat exposures (42.4 ± 0.2°C, 34.2 ± 0.9% relative humidity) on separate days while wearing a dry t-shirt (CON), a t-shirt soaked with 500 ml of tap water (WET), or a t-shirt soaked with 500 ml of tap water while facing an electric fan (2.4 ± 0.4 m/s; WET+FAN). Measurements included core and skin temperatures, evaporative mass losses, heart rate, and blood pressure. In the WET condition, elevations in core temperature were attenuated compared with DRY from 30 to 120 min and compared with WET+FAN from 30 to 90 min ( P < 0.05). Evaporative mass losses (inclusive of sweat and water losses from the shirt) were greatest in WET+FAN, followed by WET, and then DRY ( P < 0.01). Sweat losses were lowest in WET, followed by DRY, and then WET+FAN ( P < 0.01). Heart rate was lower only at 60 min in WET versus DRY ( P = 0.01). No differences in mean arterial pressure were observed ( P = 0.51). In conclusion, wearing a water-soaked t-shirt without, but not with, electric fan use is an effective heat management strategy to mitigate thermal strain and lower sweat losses in older individuals exposed to hot and moderately humid conditions. NEW & NOTEWORTHY In older individuals exposed to hot and moderately humid environments, electric fan use coupled with a water-soaked t-shirt exacerbates sweat losses without mitigating heat strain compared with a dry t-shirt. However, wearing a water-soaked t-shirt without fan use reduces sweat losses and attenuates heat strain compared with a dry t-shirt and a fan/water-soaked t-shirt combination. These findings suggest wearing a water-soaked t-shirt is an effective heat-management strategy for older individuals during heat waves when air conditioning is inaccessible.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.968
Threshold uncertainty score0.352

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.296
Teacher spread0.258 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations61
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied PhysiologySame topicClimate Change and Health ImpactsFrench-language works237,207