MétaCan
Menu
Back to cohort
Record W3006136946

Quality of electronic records documenting adverse drug reactions within a hospital setting: identification of discrepancies and information completeness.

2019· article· en· W3006136946 on OpenAlexaff
Rhiannon Braund, Courtney K. Lawrence, Lindsay Baum, Brittany Kessler, Madison Vassart, Carolyn V. Coulter

Bibliographic record

VenuePubMed · 2019
Typearticle
Languageen
FieldPharmacology, Toxicology and Pharmaceutics
TopicPharmacovigilance and Adverse Drug Reactions
Canadian institutionsUniversity of Manitoba
Fundersnot available
KeywordsMedicineDocumentationDrug allergyMedical recordElectronic dataMedical emergencyAllergyDrug reactionPatient safetyElectronic medical recordPediatricsDrugHealth careDatabaseInternal medicinePharmacology
DOInot available

Abstract

fetched live from OpenAlex

AIM: Incomplete and incorrect documentation of adverse drug reactions (ADRs) can restrict prescribing choices resulting in suboptimal pharmaceutical care. This study aimed to examine the quality of information held within electronic systems in a hospital setting, to determine the preciseness of ADR documentation, and identify discrepancies where multiple electronic systems are utilised. METHOD: Over a four-week period, consecutive patients admitted to the general medical ward at the study hospital had their electronic profiles reviewed. Patient demographic information (de-identified), ADR history and discrepancies between information sources (as recorded in all electronic systems utilised at initial prescribing) were recorded and analysed. RESULTS: Over the four-week period, 332 patient profiles were reviewed, and over 1,200 alerts were identified and analysed (including duplicates of ADR reactions). Of these patients, 151 (45.5%) had at least one documented allergy or intolerance which generated 585 reactions, relating to 526 unique events. A further 151 (45.5%) were classified as having no known (drug) allergies or intolerances; however, 20 (15%) of these patients did have at least one allergy documented in at least one other electronic system. The remaining 30 (9%) patients were classified as having an unknown allergy status and of those nine had allergies documented in at least one other electronic system. Further, most systems contained information duplication, which had not been addressed during the admission process. CONCLUSION: ADR information was both imprecise and inaccurate, as multiple discrepancies between ADR information recorded in different electronic patient management systems were found to exist. Information sharing between systems needs to be prioritised in order to allow full, accurate and complete ADR information to be collected, stored and utilised; both to reduce current inadequacies and to allow optimal pharmaceutical care.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.092
Threshold uncertainty score0.522

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.361
Teacher spread0.319 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2019
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicPharmacovigilance and Adverse Drug ReactionsFrench-language works237,207