MétaCan
Menu
Back to cohort
Record W3008957755 · doi:10.4187/respcare.07240

Oxygen Conservation Methods With Automated Titration

2020· article· en· W3008957755 on OpenAlexafffund
Stéphane Bourassa, Pierre-Alexandre Bouchard, Marc Dauphin, François Lellouche

Bibliographic record

VenueRespiratory Care · 2020
Typearticle
Languageen
FieldMedicine
TopicRespiratory Support and Mechanisms
Canadian institutionsUniversité LavalRoyal Canadian NavyInstitut universitaire de cardiologie et de pneumologie de QuébecUniversité de MontréalCanadian Armed Forces
FundersCanadian Armed Forces
KeywordsHypoxemiaTitrationOxygenationMedicineOxygenScrollAlgorithmCardiologyInternal medicineComputer sciencePhysicsChemistryEngineeringMechanical engineeringInorganic chemistry

Abstract

fetched live from OpenAlex

BACKGROUND: Oxygen titration is recommended to avoid hyperoxemia and hypoxemia. Automated titration, as well as the [Formula: see text] target, may have an impact on oxygen utilization, with potential logistical effects in emergency and military transportation. We sought to assess the oxygen flow required for different [Formula: see text] targets in spontaneously breathing subjects, and to evaluate individualized automated oxygen titration to maintain stable oxygenation in subjects with COPD and healthy subjects with induced hypoxemia. METHODS: In the first part of the study, oxygen flow was evaluated in hospitalized subjects for different [Formula: see text] targets from 90% to 98%. Oxygen requirements to reach these targets were determined using a device that automatically adjusts oxygen flow every second on the basis of the [Formula: see text] target. In the second part of the study, the same automated oxygen titration method was used to correct hypoxemia in subjects with COPD and in healthy subjects with induced hypoxemia while the subjects wore a gas mask. Oxygen flow, [Formula: see text], and heart rate were continuously recorded. RESULTS: Thirty-six spontaneously breathing hospitalized subjects were included in the first part of the study. Oxygen flow was reduced more than 6-fold when the [Formula: see text] target was decreased from 98% to 90%. The second part of the study included 15 healthy and 9 subjects with stable COPD. In healthy subjects, heterogeneous oxygen flows were required to correct induced hypoxemia (0.2-2.5 L/min). In subjects with COPD, oxygen flow varied from 0 L/min (in 9 of 18 tested conditions) to 2.9 L/min. CONCLUSIONS: Significant reductions in the amount of oxygen delivered could be obtained with optimized [Formula: see text] targets. Oxygen delivery through a gas mask to correct hypoxemia is feasible, and automated oxygen titration may help individualize oxygen administration and reduce oxygen utilization. (ClinicalTrials.gov registration: NCT02782936, NCT02809807.).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.565
Threshold uncertainty score0.521

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.054
GPT teacher head0.353
Teacher spread0.300 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".