MétaCan
Menu
Back to cohort
Record W3009537328 · doi:10.1002/mrm.28226

On the value of QSM from MPRAGE for segmenting and quantifying iron‐rich deep gray matter

2020· article· en· W3009537328 on OpenAlexafffund
Nashwan Naji, Hongfu Sun, Alan H. Wilman

Bibliographic record

VenueMagnetic Resonance in Medicine · 2020
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversity of Alberta
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchWomen and Children's Health Research Institute
KeywordsQuantitative susceptibility mappingSegmentationGradient echoNuclear medicineGlobus pallidusNuclear magnetic resonanceMagnetic resonance imagingArtificial intelligencePhysicsMedicineComputer scienceRadiologyInternal medicine

Abstract

fetched live from OpenAlex

Purpose Quantitative susceptibility mapping (QSM) has been employed for both iron evaluation and segmentation of deep gray matter (DGM), but QSM sequences are not typically used in standard brain volumetric studies, which use T1‐weighted magnetization‐prepared rapid acquisition with gradient echo (MPRAGE) with short TE. Here, QSM produced directly from standard MPRAGE phase ( ) is evaluated for segmentation and quantification of highly iron‐rich DGM regions. Methods Simulations were used to explore quality and possible limitations. In addition, QSM from a standard multi‐echo gradient‐echo ( ) was compared to in 40 healthy adults at 3T. DGM structures with weak contrast on MPRAGE magnitude were evaluated for improving segmentation with , with focus on the iron‐rich globus pallidus (GP). Furthermore, susceptibility quantification was assessed on six DGM nuclei and compared to standard . Results Limited by TE and signal‐to‐noise ratio, only iron‐rich regions like GP and dentate nucleus produced adequate contrast on , confining applications to such regions. improved GP segmentation with mean Dice scores raised by 9.0%, and mean volumetric differences reduced by 9.7%. Simulations suggested that phase contrast‐to‐noise ratio (CNR) should be above 3.0 to attain segmentation improvement. For quantification purposes, higher CNR is required, and typical provided comparable estimates to in large iron‐rich DGM nuclei. Conclusion Despite the short TE of standard MPRAGE, can improve GP segmentation over the use of MPRAGE magnitude alone and roughly quantify high‐iron regions in DGM. Thus, reconstructing can be a useful addition to volumetric studies that rarely include standard .

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.005
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.040
GPT teacher head0.324
Teacher spread0.284 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207