MétaCan
Menu
Back to cohort
Record W3009721182 · doi:10.29390/cjrt-2019-025

Variability in expiratory flow requirements among oscillatory positive expiratory pressure devices

2020· article· en· W3009721182 on OpenAlexvenueno aff
Sherwin Morgan, Steven Mosakowski, B. Louise Giles, Edward T. Naureckas, Avery Tung

Bibliographic record

VenueCanadian Journal of Respiratory Therapy · 2020
Typearticle
Languageen
FieldMedicine
TopicInhalation and Respiratory Drug Delivery
Canadian institutionsnot available
Fundersnot available
KeywordsMedicinePositive end-expiratory pressureCOPDAirflowCardiologyAnesthesiaBiomedical engineeringInternal medicineMechanical ventilationEngineeringMechanical engineering

Abstract

fetched live from OpenAlex

Introduction: Oscillatory positive expiratory pressure (OPEP) devices facilitate secretion clearance by generating positive end expiratory pressure.However, different device designs may produce different levels of expiratory pressure with the same expiratory flow rate.We bench tested four devices to determine the relationship between expiratory flow and expiratory pressure in each.Methods: A bench model was created to test the gas flow rates required by different OPEP devices to generate target expiratory pressure.Four different devices were tested: Acapella ® (DH Green, Smiths Medical), AerobiKa ® (Monaghan Medical Corporation), VibraPEP ® (Curaplex), and vPEP™ (D R Burton Healthcare).Each OPEP device was tested to determine the expiratory flow needed to generate expiratory pressure thresholds considered appropriate for OPEP therapy.Results: The expiratory flow required to generate the same expiratory pressure thresholds varied considerably among devices.Valved OPEP devices such as the VibraPEP required less flow than mechanical devices such as the vPEP, Aerobika, and Acapella.Discussion: In this bench test of OPEP devices, we found considerable variability in expiratory flow requirements needed to generate an expiratory pressure of >10 cm H 2 O.Our finding suggests that smaller patients or those with limited expiratory airflow due to diseases such as COPD, obesity, chronic congestive heart failure, and restrictive lung disease may have better results when matched to OPEP devices requiring less expiratory airflow.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.018

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.012
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.272
Teacher spread0.229 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueCanadian Journal of Respiratory TherapySame topicInhalation and Respiratory Drug DeliveryFrench-language works237,207