MétaCan
Menu
Back to cohort
Record W3010458352 · doi:10.1002/uog.22012

Diagnostic accuracy of postmortem ultrasound <i>vs</i> postmortem 1.5‐T MRI for non‐invasive perinatal autopsy

2020· article· en· W3010458352 on OpenAlex
Susan C. Shelmerdine, Neil J. Sebire, Owen J. Arthurs

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

fundA Canadian funder is recorded on the work.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueUltrasound in Obstetrics and Gynecology · 2020
Typearticle
Languageen
FieldMedicine
TopicAutopsy Techniques and Outcomes
Canadian institutionsnot available
FundersMedical Research Council CanadaRoyal College of RadiologistsMedical Research CouncilNational Institute for Health and Care Research
KeywordsMedicineAutopsyConcordanceMagnetic resonance imagingRadiologyProspective cohort studyThorax (insect anatomy)Nuclear medicineSurgeryPathologyInternal medicineAnatomy

Abstract

fetched live from OpenAlex

OBJECTIVES: To determine the diagnostic accuracy of postmortem magnetic resonance imaging (PM-MRI) and postmortem ultrasound (PM-US) for perinatal autopsy in the same patient cohort, and to determine whether PM-US can provide the same anatomical information as PM-MRI. METHODS: In this prospective, 5-year (July 2014-July 2019) single-center study, we performed 1.5-T PM-MRI and PM-US in an unselected cohort of perinatal deaths. The diagnostic accuracies of both modalities were calculated, using autopsy as the reference standard. As a secondary objective, the concordance rates between the two imaging modalities for the overall main diagnosis and for five anatomical regions (brain, spine, thorax, heart and abdomen) were calculated. RESULTS: During the study period, 136 cases underwent both PM-US and PM-MRI, of which 88 (64.7%) also underwent autopsy. There was no significant difference in the rates of concordance with autopsy between the two modalities for overall diagnosis (PM-US, 86.4% (95% CI, 77.7-92.0%) vs PM-MRI, 88.6% (95% CI, 80.3-93.7%)) or in the sensitivities and specificities for individual anatomical regions. There were more non-diagnostic PM-US than PM-MRI examinations for the brain (22.8% vs 3.7%) and heart (14.7% vs 5.1%). If an 'imaging-only' autopsy had been performed, PM-US would have achieved the same diagnosis as 1.5-T PM-MRI in 86.8% (95% CI, 80.0-91.5%) of cases, with the highest rates of agreement being for spine (99.3% (95% CI, 95.9-99.9%)) and cardiac (97.3% (95% CI, 92.4-99.1%)) findings and the lowest being for brain diagnoses (85.2% (95% CI, 76.9-90.8%)). CONCLUSION: Although there were fewer non-diagnostic cases using PM-MRI than for PM-US, the high concordance rate for overall diagnosis suggests that PM-US could be used for triaging cases when PM-MRI access is limited or unavailable. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.152
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch, Meta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.152
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.152
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.272
Teacher spread0.258 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it