MétaCan
Menu
← Back to cohort
Record W3013802970 · doi:10.82308/49752

Image guided radiation therapy applications for head and neck, prostate, and breast cancers using 3D ultrasound imaging and Monte Carlo dose calculations

2010· article· en· W3013802970 on OpenAlexaboutno aff
D Fraser

Bibliographic record

VenueeScholarship@McGill (McGill) · 2010
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineHead and neckRadiation therapyUltrasoundProstateRadiologyImage-guided radiation therapyMedical physicsSurgeryCancerInternal medicine

Abstract

fetched live from OpenAlex

Des incertitudes dans la dose délivrée aux patients existent toujours car les changements anatomiques sont imprévisibles et spécifiques à chaque patient. La radiothérapie guidée par l'image (IGRT) dépend de l'imagerie en ligne afin de suivre la tumeur et les tissus sains adjacents, et s'assure que leur positions, par rapport au faisceau de radiation, est telle que planifiés. L'objectif de cette thèse a été de déterminer l'impact dosimétrique du désalignement de la cible par rapport au faisceau de radiation du aux erreurs d'installation, aux mouvement des organes, à la déformation de la tumeur, aux changements de l'habitus du corps et aux erreurs dans la planification du traitement. À cette fin, un nouveau système ultrason 3D (Restitu, Resonant Medical, Inc.) a été utilisé pour acquérir des images référence de la cible dans la salle de simulation tomodensitométrique au moment de la planification du traitement, et ensuite pour acquérir des images quotidiennes de la cible au moment du traitement. Les images quotidiennes ont été comparées à l'image de référence et les différences de position et volume ont été incorporées dans des calculs de dose Monte Carlo. La famille de logiciels EGSNRC (National Research Council, Canada) a été utilisée pour modéliser des accélérateurs linéaires Varian et des paramètres spécifiques à chaque patient ainsi que pour estimer la dose à la cible et aux organes à risque. Premièrement, les calculs de dose Monte Carlo, longs mais précis, ont été validés pour la région homogène du pelvis. Ensuite, l'influence du mouvement de la prostate inter fractions et du réalignement du patient sur la distribution de dose délivrée a été investiguée. Pour 32 patients nous avons démontré que l'utilisation des techniques conformes 3D combinée à une marge de 7 mm autour de la cible se traduit par une différence de moins de 0.5% entre la dose délivrée et la dose planifiée pour la prostate,$

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.005
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.284
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueeScholarship@McGill (McGill)→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→