Effect of inclisiran, the small-interfering RNA against proprotein convertase subtilisin/kexin type 9, on platelets, immune cells, and immunological biomarkers: a pre-specified analysis from ORION-1
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
AIMS: Small-interfering RNA (siRNA)-based targeting of proprotein convertase subtilisin/kexin type 9 (PCSK9) represents a novel therapeutic approach that may provide a convenient, infrequent, and safe dosing schedule to robustly lower low-density lipoprotein cholesterol (LDL-C). Given the long duration of action, however, establishing safety in particular with respect to immunogenicity is of paramount importance. In earlier clinical studies of other RNA-targeted treatment approaches (antisense oligonucleotide therapy) immunological and haematological adverse effects, in particular thrombocytopenia and pro-inflammatory effects, have been reported. Here, we present the pre-specified safety analysis from ORION-1 evaluating platelets, immune cells, immunological markers, antidrug antibodies, and clinical immunogenicity adverse events (AEs) under PCSK9 siRNA treatment with inclisiran. METHODS AND RESULTS: The pre-specified safety analysis from ORION-1 was performed in six different inclisiran dosing regimens in patients at high risk of cardiovascular disease with elevated LDL-C levels. Patients received either a single dose (SD: 200 mg, n = 60; 300 mg, n = 62 or 500 mg, n = 66) or double-dose starting regimen (DD: 100 mg, n = 62; 200 mg, n = 63; or 300 mg, n = 61 on days 1 and 90) of inclisiran or placebo (SD: n = 65; DD: n = 62). The effects of inclisiran on haematological parameters including platelet counts, lymphocytes, and monocytes as well as on the immune markers interleukin 6 (IL-6) and tumour necrosis factor-α (TNF-α) were examined after 180 days. Immunogenicity was further evaluated by analysis of anti-drug-antibodies (ADAs) towards inclisiran in 6068 study samples and by careful analysis of immunogenicity AEs as part of the pharmacovigilance strategy. At day 180, no significant alterations of platelet counts were observed in any of the dosing groups (change from baseline, SD: 200 mg: 0.8%; 300 mg: -0.5%; 500 mg: -1.8%; DD: 100 mg: 1.3%; 200 mg: -0.5%; 300 mg: 1.0%; no significant difference for any group as compared with placebo). No significant effects on other immune cells, including leucocytes, monocytes, or neutrophils were detected. Notably, no significant increase of inflammatory biomarkers (IL-6 or TNF-α) with either the SD or DD regimen became evident. There was no evidence for immunogenicity based on ADA level analysis and careful review of clinical immunogenicity AEs in none of the treatment regimens. CONCLUSION: In this pre-specified safety analysis of ORION-1 for the siRNA therapeutic inclisiran, no adverse effects on measures of inflammation or immune activation nor adverse effects on platelets or clinical immunogenicity AEs were observed over at least 6-month treatment. These safety findings in the largest analysis of an RNAi study in humans to date provide strong reassurance about the safety of inclisiran and the potential of cardiovascular RNA-targeted therapies.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.005 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.000 | 0.002 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.000 | 0.002 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it