Effectiveness of a lumbopelvic monitor and feedback device to change postural behaviour: the ELF cluster randomised controlled trial

2020· article· en· W3015102067 on OpenAlexaff
Daniel Cury Ribeiro, Stephan Milosavljevic, Jane Terry, J. Haxby Abbott

Bibliographic record

VenueOccupational and Environmental Medicine · 2020
Typearticle
Languageen
FieldMedicine
TopicMusculoskeletal pain and rehabilitation
Canadian institutionsUniversity of Saskatchewan
FundersHealth Research Council of New ZealandLottery Health Research
KeywordsPhysical therapyMedicineRandomized controlled trialPhysical medicine and rehabilitationHealth careCluster randomised controlled trialCluster (spacecraft)Computer scienceSurgery

Abstract

fetched live from OpenAlex

OBJECTIVES: The aim of this clustered, randomised controlled trial was to assess the effectiveness of a lumbopelvic postural feedback device for changing postural behaviour in a group of healthcare workers. We hypothesised that workers exposed to auditory postural feedback would reduce the number of times forward bending posture is adopted at work. METHODS: This was a participant and assessor blinded, randomised, sham-controlled trial with blocked cluster random allocation. We recruited healthcare workers from aged care institutions. Healthcare sites were randomly allocated to the feedback or sham group (SG). A postural monitoring and feedback device was used to monitor and record lumbopelvic forward bending posture, and provided audio feedback whenever the user sustained lumbopelvic forward bending posture that exceeded predefined thresholds. The primary outcome measure was postural behaviour (exceeding thresholds). We used a robust variant of repeated measures mixed-effect model for assessing within-group and between-group differences in postural behaviour. RESULTS: We recruited 19 sites, and 130 healthcare workers participated. There were no within-group changes on the number of times postural threshold was exceeded at 1-week follow-up (feedback group: -0.7, 95% CI -2.61 to 0.72; SG -0.3, -1.65 to 0.98), and no differences (0.05, 95% CI -1.83 to 1.94) between SG and feedback group. CONCLUSIONS: Findings from this trial indicate that audio feedback provided by a postural monitor device did not reduce the number of times healthcare workers exceeded the postural threshold. TRIAL REGISTRATION NUMBER: ACTRN12616000449437.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.015
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.037

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0070.015
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0060.003
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0010.002
Open science0.0020.001
Research integrity0.0050.003
Insufficient payload (model declined to judge)0.0100.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.279
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".