Dose‐rate considerations for the INTRABEAM electronic brachytherapy system: Report from the American Association of Physicists in Medicine task group no. 292
Bibliographic record
Abstract
The purpose of this report is to provide detailed guidance on the dosimetry of the INTRABEAM® (Carl Zeiss Medical AG, Jena, Germany) electronic brachytherapy (eBT) system as it stands at the present time. This report has been developed by the members of American Association of Physicists in Medicine (AAPM) Task Group 292 and endorsed by the AAPM. Members of AAPM Task Group 292 on Electronic-Brachytherapy Dosimetry have reviewed pertinent publications and user manuals regarding the INTRABEAM system dosimetry and manufacturer-supplied dose calculation protocols. Formal written correspondence with Zeiss has also provided further clarification. Dose-rate calculations for the INTRABEAM system are highly dependent on choice of dosimetry protocol. Even with careful protocol selection, large uncertainties remain due to the incomplete characterization of the ionization chambers used for verification with respect to their energy dependence as well as manufacturing variations. There are two distinct sets of dose-rate data provided by Zeiss for the INTRABEAM system. One dataset (Calibration V4.0) is representative of the physical dose surrounding the source and the other dataset (TARGIT) has been adjusted to be consistent with a clinical trial named TARGIT (TARGeted Intraoperative RadioTherapy). The adjusted TARGIT doses are quite dissimilar to the physical doses, with differences ranging from 14% to 30% at the surface of a spherical applicator, depending on its diameter, and up to a factor of two at closer distances with the smaller needle applicators. In addition, ion chamber selection and associated manufacturing tolerances contribute to significant additional uncertainties. With these substantial differences in dose rates and their associated uncertainties, it is important for users to be aware of how each value is calculated and whether it is appropriate to be used for the intended treatment. If users intend to deliver doses that are the same as they were in 1998 at the onset of the TARGIT trial, then the TARGIT dose-rate tables should be used. The Calibration V4.0 dose rates may be more appropriate to use for applications other than TARGIT trial treatments, since they more closely represent the physical doses being delivered. Users should also be aware of the substantial uncertainties associated with the provided dose rates, which are due to beam hardening, chamber geometry, and selection of the point-of-measurement for a given ionization chamber. This report serves to describe the details and implications of the manufacturer-recommended dosimetry formalism for users of the INTRABEAM system.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.033 | 0.023 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.001 | 0.002 |
| Bibliometrics | 0.003 | 0.004 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.003 | 0.002 |
| Open science | 0.004 | 0.002 |
| Research integrity | 0.004 | 0.003 |
| Insufficient payload (model declined to judge) | 0.004 | 0.004 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".