MétaCan
Menu
Back to cohort
Record W3015374459 · doi:10.18462/iir.icr.2019.0134

Performance of R466A, a non-flammable replacement for R410A, in unitary air-conditioning and transport refrigeration.

2021· article· en· W3015374459 on OpenAlexaboutno aff
K Schultz

Bibliographic record

VenueInstitut International du Froid · 2021
Typearticle
Languageen
FieldEngineering
TopicRefrigeration and Air Conditioning Technologies
Canadian institutionsnot available
Fundersnot available
KeywordsFlammable liquidAir conditioningHVACChillerRefrigerantRefrigerationEnvironmental scienceHeat pumpConditioningProcess engineeringThermodynamicsEngineeringStatisticsMathematicsHeat exchanger

Abstract

fetched live from OpenAlex

Use of R410A is under pressure to be phased down because of its high global warming potential (GWP). The recent Kigali amendment to the Montreal Protocol will necessitate the phase-out of R410A used in air conditioning systems in developed countries by the late 2020s. This will require the industry to begin using R410A replacements by the middle 2020s. A new refrigerant blend, R466A, has been developed with thermodynamic properties that potentially make it a design compatible replacement for R410A. This new blend offers a 65 % reduction in GWP over R410A and is non-flammable (Class A1). Tests of a blend with very similar composition in an air-cooled chiller and a residential split system heat pump were previously reported. Performance generally met expectations with capacity being slightly lower than R410A and efficiency being slightly lower than R410A in the chiller test and similar to positive in the heat pump test, all consistent with the thermodynamic properties of R466A relative R410A. This paper presents the results of tests run with R410A (as baseline) and R466A in another residential heat pump and a transport refrigeration unit. Again, performance is generally seen to meet expectations. Capacities ranged from -5 % to +2 % relative to the R410A baselines. Efficiencies ranged from -3 % to +4 % relative to the R410A baselines. These results demonstrate R466A's utility as a lower GWP, design compatible replacement for R410A in a range of HVAC&R equipment. Its classification as non-flammable permits R466A to be used in existing equipment designs, either in new product or as field replacement of reclaimed R410A.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.241
Threshold uncertainty score0.436

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.204
Teacher spread0.198 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueInstitut International du FroidSame topicRefrigeration and Air Conditioning TechnologiesFrench-language works237,207