MétaCan
Menu
Back to cohort
Record W3020327143 · doi:10.1007/s12350-020-02200-6

Rubidium-82 generator yield and efficiency for PET perfusion imaging: Comparison of two clinical systems

2020· article· en· W3020327143 on OpenAlexaff
Ali Ahmadi, Ran Klein, Howard C. Lewin, Rob Beanlands, Robert A. deKemp

Bibliographic record

VenueJournal of Nuclear Cardiology · 2020
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsOttawa HospitalUniversity of Ottawa
Fundersnot available
KeywordsMedicineNuclear medicineYield (engineering)PerfusionPositron emission tomographyCardiac PETPerfusion scanningMyocardial perfusion imagingMaterials scienceInternal medicine

Abstract

fetched live from OpenAlex

Strontium-82/Rubidium-82 ( 82 Sr/ 82 Rb) generators are used widely for positron emission tomography (PET) imaging of myocardial perfusion. In this study, the 82 Rb isotope yield and production efficiency of two FDA-approved 82 Sr/ 82 Rb generators were compared. N = 515 sequential daily quality assurance (QA) reports from 9 CardioGen-82 ® and 9 RUBY-FILL ® generators were reviewed over a period of 2 years. A series of test elutions was performed at different flow-rates on the RUBY-FILL ® system to determine an empirical correction-factor used to convert CardioGen-82 ® daily QA values of 82 Rb activity (dose-calibrator ‘maximum’ of 50 mL elution at 50 mL·min −1 ) to RUBY-FILL ® equivalent values (integrated ‘total’ of 35 mL elution at 20 mL·min −1 ). The generator yield ( 82 Rb) and production efficiency ( 82 Rb yield/ 82 Sr parent activity) were measured and compared after this conversion to a common scale. At the start of clinical use, the system reported 82 Rb activity from daily QA was lower for CardioGen-82 ® vs RUBY-FILL ® (2.3 ± 0.2 vs 3.0 ± 0.2 GBq, P < 0.001) despite having similar 82 Sr activity. Dose-calibrator ‘maximum’ (CardioGen-82 ® ) values were found to under-estimate the integrated ‘total’ (RUBY-FILL ® ) activity by ~ 24% at 50 mL·min −1 . When these data were used to convert the CardioGen-82 values to a common measurement scale (integrated total activity) the CardioGen-82 ® efficiency remained slightly lower than the RUBY-FILL ® system on average (88 ± 4% vs 95 ± 4%, P < 0.001). The efficiency of 82 Rb production improved for both systems over the respective periods of clinical use. 82 Rb generator yield was significantly under-estimated using the CardioGen-82 ® vs RUBY-FILL ® daily QA procedure. When generator yield was expressed as the integrated total activity for both systems, the estimated 82 Rb production efficiency of the CardioGen-82 ® system was ~ 7% lower than RUBY-FILL ® over the full period of clinical use.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.293
Threshold uncertainty score0.229

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.094
GPT teacher head0.401
Teacher spread0.307 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Nuclear CardiologySame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207