MétaCan
Menu
Back to cohort
Record W3021361205 · doi:10.1101/2020.05.02.20080879

Validation of a commercially available SARS-CoV-2 serological Immunoassay

2020· preprint· en· W3021361205 on OpenAlexaff
Benjamin Meyer, Giulia Torriani, Sabine Yerly, Léna Mazza, Adrien Calame, Isabelle Arm‐Vernez, Gert Zimmer, Thomas Agoritsas, Jérôme Stirnemann, Hervé Spechbach, Idris Guessous, Silvia Stringhini, Jérôme Pugin, Pascale Roux‐Lombard, Lionel Fontao, Claire‐Anne Siegrist, Isabella Eckerle, Nicolas Vuilleumier, Laurent Kaiser

Bibliographic record

VenuemedRxiv · 2020
Typepreprint
Languageen
FieldMedicine
TopicSARS-CoV-2 and COVID-19 Research
Canadian institutionsImpact
FundersHôpitaux Universitaires de GenèveGeorg-August-Universität Göttingen
KeywordsSerologyImmunoassayReceiver operating characteristicConfidence intervalMedicineCoronavirus disease 2019 (COVID-19)Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)AntibodyArea under the curvePredictive valueImmunologyDiagnostic accuracyInternal medicineGastroenterologyVirology

Abstract

fetched live from OpenAlex

Abstract Objectives To validate the diagnostic accuracy of a Euroimmun SARS-CoV-2 IgG and IgA immunoassay for COVID-19. Methods In this unmatched (1:1) case-control validation study, we used sera of 181 laboratory-confirmed SARS-CoV-2 cases and 176 controls collected before SARS-CoV-2 emergence. Diagnostic accuracy of the immunoassay was assessed against a whole spike protein-based recombinant immunofluorescence assay (rIFA) by receiver operating characteristic (ROC) analyses. Discrepant cases between ELISA and rIFA were further tested by pseudo-neutralization assay. Results COVID-19 patients were more likely to be male and older than controls, and 50.3% were hospitalized. ROC curve analyses indicated that IgG and IgA had high diagnostic accuracies with AUCs of 0.992 (95% Confidence Interval [95%CI]: 0.986-0.996) and 0.977 (95%CI: 0.963-0.990), respectively. IgG assays outperformed IgA assays (p=0.008). Taking an assessed 15% inter-assay imprecision into account, an optimized IgG ratio cut-off > 1.5 displayed a 100% specificity (95%CI: 98–100) and a 100% positive predictive value (95%CI: 97-100). A 0.5 cut-off displayed a 97% sensitivity (95%CI: 93–99) and a 97% negative predictive value (95%CI: 93–99). Substituting these thresholds for the manufacturer’s, improved assay performance, leaving 12% of IgG ratios indeterminate between 0.5-1.5. Conclusions The Euroimmun assay displays a nearly optimal diagnostic accuracy using IgG against SARS-CoV-2 in patient samples, with no obvious gains from IgA serology. The optimized cut-offs are fit for rule-in and rule-out purposes, allowing determination of whether individuals in our study population have been exposed to SARS-CoV-2 or not. IgG serology should however not be considered as a surrogate of protection at this stage.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.016
metaresearch head score (Gemma)0.016
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.016
Threshold uncertainty score0.085

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0160.016
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.127
GPT teacher head0.373
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations35
Published2020
Admission routes1
Has abstractyes

Explore more

Same venuemedRxivSame topicSARS-CoV-2 and COVID-19 ResearchFrench-language works237,207