MétaCan
Menu
Back to cohort
Record W3021959355 · doi:10.1088/1361-6579/ab921f

Investigating coherent normalization and dosimetry for the <sup>241</sup> Am-La K XRF system

2020· article· en· W3021959355 on OpenAlexafffund
Joanna Nguyen, Ana Pejović‐Milić, James L Gräfe

Bibliographic record

VenuePhysiological Measurement · 2020
Typearticle
Languageen
FieldMaterials Science
TopicRadiation Shielding Materials Analysis
Canadian institutionsToronto Metropolitan University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsNormalization (sociology)DosimetryPhysicsRadiochemistryComputer scienceNuclear medicineChemistryMedicine

Abstract

fetched live from OpenAlex

Abstract Objectives : Lanthanum (La) retention in bone has been shown to occur in individuals who are orally administered lanthanum carbonate (LaC), a drug to treat hyperphosphatemia. The breakdown of LaC in the gastrointestinal tract into La 3+ and carbonate ions results in residual quantities of La being deposited in bone. We previously reported on a non-invasive x-ray fluorescence (XRF) system that was developed to quantify bone La concentrations and applied it to a series of excised cadaver tibiae. However, given interpatient variability in bone shape and size, differential signal attenuation that occurs in bone and tissue, patient movement and overlying tissue thickness at the measurement site, quantifying bone La concentrations during in vivo measurements in live subjects needs to be investigated further along with the radiation dose associated with the measurement. Approach : Coherent normalization was investigated as a function of overlying tissue thickness, source-subject distance and bone radius through Monte Carlo simulation and experimental work. This was accomplished by observing the ratio of the net La K x-ray peak area to the coherently scattered peak area at 59.5 keV. In addition, the dose delivered during a 2000 s measurement was determined using radiochromic film. Main results : The coherent normalization of the La x-ray signal was shown to be independent of overlying tissue thickness, source-subject movement and bone radius, which indicates that this normalization procedure can correct for these factors. The equivalent skin dose and effective dose were 18.0 mSv and 3.2 μSv, respectively for a five-year-old. Significance : While coherent normalization for the bone lead (Pb) and bone gadolinium (Gd) systems has been shown to be successful, we also report that this normalization procedure can correct for these interpatient variabilities in the in vivo 241 Am-La K XRF system.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.100
GPT teacher head0.265
Teacher spread0.164 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2020
Admission routes2
Has abstractyes

Explore more

Same venuePhysiological MeasurementSame topicRadiation Shielding Materials AnalysisFrench-language works237,207