Dosimetric impact of tracheostomy devices in head and neck cancer patients
Bibliographic record
Abstract
INTRODUCTION: The tracheostomy site and adjacent skin is at risk for recurrence in head/neck squamous cell cancer patients. The tracheostomy tube is an in situ device located directly over the tracheostomy site and may have clinical implications on the radiation dose delivered to the peristomal region. This study aimed to investigate this effect by comparing the prescribed treatment planning dose with the actual dose in vivo to the peristomal clinical target region. A retrospective, dosimetric study was performed with approval of the institutional research ethics board. METHODS: Fifteen patients who had received high-dose radiotherapy to the tracheostomy region with in vivo dose measurements were included. The radiation dose at the skin surface underneath the tracheostomy device was measured using an optically stimulated luminescent dosimeter (OSLD) and was compared with the prescribed dose from the radiation planning system. The effect of the tracheostomy flange and/or soft tissue equivalent bolus on the peristomal dose was calculated. RESULTS AND DISCUSSION: Patients with tracheostomy equipment in situ were found to have a 3.7% difference between their prescribed and actual dose. With a tissue equivalent bolus there was a 2.0% difference between predicted and actual. The mean prescribed single fraction dose (mean = 191.8 cGy, SD = 40.18) and OSLD measured dose (mean = 194.02 cGy, SD = 44.3) were found to have no significant difference. However, with the flange excluded from the planning simulation (density = air) target skin dose deviated from predicted by an average of 55.3% (range = 12.4-72.9, SD = 22.5) and volume coverage was not achieved. CONCLUSION: In summary, the tracheostomy flange acts like bolus with a twofold increase in the skin surface dose. Changes in the peristomal apparatus from simulation to treatment needs to be considered to ensure that the simulated dose and coverage is achieved.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".