MétaCan
Menu
Back to cohort
Record W3023995687 · doi:10.1177/1129729820916113

Peripherally inserted central catheters inserted with current best practices have low deep vein thrombosis and central line–associated bloodstream infection risk compared with centrally inserted central catheters: A contemporary meta-analysis

2020· review· en· W3023995687 on OpenAlex
Gregory J. Schears, Nicole Ferko, Imran Syed, John-Michael Arpino, Kimberly Alsbrooks

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

aboutThe title or abstract carries a Canadian signal from the geographic lexicon.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueThe Journal of Vascular Access · 2020
Typereview
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsnot available
FundersBD Biosciences
KeywordsCentral lineBloodstream infectionMedicinePeripherally inserted central catheterDeep veinThrombosisVeinSurgeryCatheterIntensive care medicine

Abstract

fetched live from OpenAlex

Background: Peripherally inserted central catheters and centrally inserted central catheters have numerous benefits but can be associated with risks. This meta-analysis compared central catheters for relevant clinical outcomes using recent studies more likely to coincide with practice guidelines. Methods: Several databases, Ovid MEDLINE, Embase, and EBM Reviews were searched for articles (2006–2018) that compared central catheters. Analyses were limited to peer-reviewed studies comparing peripherally inserted central catheters to centrally inserted central catheters for deep vein thrombosis and/or central line–associated bloodstream infections. Subgroup, sensitivity analyses, and patient-reported measures were included. Risk ratios, incidence rate ratios, and weighted event risks were reported. Study quality assessment was conducted using Newcastle–Ottawa and Cochrane Risk of Bias scales. Results: Of 4609 screened abstracts, 31 studies were included in these meta-analyses. Across studies, peripherally inserted central catheters were protective for central line–associated bloodstream infection (incidence rate ratio = 0.52, 95% confidence interval: 0.30–0.92), with consistent results across subgroups. Peripherally inserted central catheters were associated with an increased risk of deep vein thrombosis (risk ratio = 2.08, 95% confidence interval: 1.47–2.94); however, smaller diameter and single-lumen peripherally inserted central catheters were no longer associated with increased risk. The absolute risk of deep vein thrombosis was calculated to 2.3% and 3.9% for smaller diameter peripherally inserted central catheters and centrally inserted central catheters, respectively. On average, peripherally inserted central catheter patients had 11.6 more catheter days than centrally inserted central catheter patients ( p = 0.064). Patient outcomes favored peripherally inserted central catheters. Conclusion: When adhering to best practices, this study demonstrated that concerns related to peripherally inserted central catheters and deep vein thrombosis risk are minimized. Dramatic changes to clinical practice over the last 10 years have helped to address past issues with central catheters and complication risk. Given the lower rate of complications when following current guidelines, clinicians should prioritize central line choice based on patient therapeutic needs, rather than fear of complications. Future research should continue to consider contemporary literature over antiquated data, such that it recognizes the implications of best practices in modern central catheterization.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Science and technology studies, Research integrity
Consensus categoriesMeta-epidemiology (narrow)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.071
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0090.006
Bibliometrics0.0010.003
Science and technology studies0.0020.000
Scholarly communication0.0010.002
Open science0.0020.000
Research integrity0.0010.005
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.238
GPT teacher head0.430
Teacher spread0.193 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it