MétaCan
Menu
Back to cohort
Record W3027306138 · doi:10.3791/61053

A Hydrogen-Deuterium Exchange Mass Spectrometry (HDX-MS) Platform for Investigating Peptide Biosynthetic Enzymes

2020· article· en· W3027306138 on OpenAlexaff
Yeganeh Habibi, Christopher J. Thibodeaux

Bibliographic record

VenueJournal of Visualized Experiments · 2020
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsMcGill University
Fundersnot available
KeywordsHydrogen–deuterium exchangeChemistryPeptideEnzymeDeuteriumMass spectrometryAllosteric regulationProtein dynamicsProtein structureSubstrate (aquarium)BiophysicsBiochemistryChromatography

Abstract

fetched live from OpenAlex

Hydrogen-deuterium exchange mass spectrometry (HDX-MS) is a powerful method for the biophysical characterization of enzyme conformational changes and enzyme-substrate interactions. Among its many benefits, HDX-MS consumes only small amounts of material, can be performed under near native conditions without the need for enzyme/substrate labeling, and can provide spatially resolved information on enzyme conformational dynamics-even for large enzymes and multiprotein complexes. The method is initiated by the dilution of the enzyme of interest into buffer prepared in D2O. This triggers the exchange of protium in peptide bond amides (N-H) with deuterium (N-D). At the desired exchange time points, reaction aliquots are quenched, the enzyme is proteolyzed into peptides, the peptides are separated by ultra-performance liquid chromatography (UPLC), and the change in mass of each peptide (due to the exchange of hydrogen for deuterium) is recorded by MS. The amount of deuterium uptake by each peptide is strongly dependent on the local hydrogen bonding environment of that peptide. Peptides present in very dynamic regions of the enzyme exchange deuterium very rapidly, whereas peptides derived from well-ordered regions undergo exchange much more slowly. In this manner, the HDX rate reports on local enzyme conformational dynamics. Perturbations to deuterium uptake levels in the presence of different ligands can then be used to map ligand binding sites, identify allosteric networks, and to understand the role of conformational dynamics in enzyme function. Here, we illustrate how we have used HDX-MS to better understand the biosynthesis of a type of peptide natural products called lanthipeptides. Lanthipeptides are genetically encoded peptides that are post-translationally modified by large, multifunctional, conformationally dynamic enzymes that are difficult to study with traditional structural biology approaches. HDX-MS provides an ideal and adaptable platform for investigating the mechanistic properties of these types of enzymes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.051
GPT teacher head0.381
Teacher spread0.330 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Visualized ExperimentsSame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207