MétaCan
Menu
Back to cohort
Record W3031009175 · doi:10.1016/j.crphys.2020.05.001

A comparison of pain responses, hemodynamic reactivity and fibre type composition between Bergström and microbiopsy skeletal muscle biopsies

2020· article· en· W3031009175 on OpenAlexafffundabout
Jacob T. Bonafiglia, Hashim Islam, Nicholas Preobrazenski, P Drouin, Andrew Ma, Austin Gerhart, Joe Quadrilatero, Michael E. Tschakovsky, Dean A. Tripp, Christopher G. R. Perry, Craig A. Simpson, Brendon J. Gurd

Bibliographic record

VenueCurrent Research in Physiology · 2020
Typearticle
Languageen
FieldMedicine
TopicMusculoskeletal pain and rehabilitation
Canadian institutionsYork UniversityUniversity of WaterlooQueen's University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsSkeletal muscleBiopsyHemodynamicsMuscle biopsyMedicineChemistryAnatomyInternal medicine

Abstract

fetched live from OpenAlex

This study tested the hypotheses that 1) skeletal muscle biopsies performed with the Bergström needle evoke larger perceptions of pain and greater hemodynamic reactivity compared to biopsies performed with the microbiopsy needle, and 2) both needles yield samples with similar fibre type compositions when samples are collected at similar skeletal muscle depths. Fourteen healthy (age: 21.6 ± 3.2 years; VO2peak: 41.5 ± 5.8 mL/kg/min) males (n = 7) and females (n = 7) provided two resting skeletal muscle biopsies, one with each needle type, following a randomized crossover design. Participants completed the short-form McGill Pain Questionnaire and the Brief Pain Inventory before, during, and after the skeletal muscle biopsies. Hemodynamic reactivity was assessed by measuring heart rate (HR) and mean arterial pressure (MAP) at rest and during the biopsy procedures. Immunofluorescence analysis was used to assess fibre type composition in vastus lateralis samples. Compared to the microbiopsy needle, the Bergström needle elicited a larger perception of pain but similar hemodynamic reactivity during the biopsy. Both needles yielded skeletal muscle samples with similar fibre type composition and resulted in similar perceptions of pain and pain-related interference during the post-biopsy recovery period. Collectively, these findings suggest that studies should consider using the microbiopsy needle rather than the Bergström needle unless large amounts of muscle tissue or certain muscle fibre lengths are required. However, future work should determine whether our findings are generalizable to biopsies performed with different procedures and/or types of Bergström/microbiopsy needles.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.099
GPT teacher head0.432
Teacher spread0.334 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2020
Admission routes3
Has abstractyes

Explore more

Same venueCurrent Research in PhysiologySame topicMusculoskeletal pain and rehabilitationFrench-language works237,207