A newly designed uncovered biliary stent for palliation of malignant obstruction: results of a prospective study
Bibliographic record
Abstract
BACKGROUND: Biliary decompression can reduce symptoms and improve quality of life in patients with malignant biliary obstruction. Endoscopically placed stents have become the standard of care for biliary drainage with the aim of improving hepatic function, relieving jaundice, and reducing adverse effects of obstruction. The purpose of this study was to evaluate the performance characteristics of a newly-designed, uncovered metal biliary stent for the palliation of malignant biliary obstruction. METHODS: This post-market, prospective study included patients with biliary obstruction due to a malignant neoplasm treated with a single-type, commercially available uncovered self-expanding metal stent (SEMS). Stents were placed as clinically indicated for palliation of jaundice and to potentially facilitate neo-adjuvant chemotherapy. The main outcome measure was freedom from recurrent biliary obstruction (within the stent) requiring re-intervention within 1, 3, and 6 months of stent insertion. Secondary outcome measures included device-related adverse events and technical success of stent deployment. RESULTS: SEMS were placed in 113 patients (73 men; mean age, 69); a single stent was inserted in 106 patients, and 2 stents were placed in 7 patients. Forty-eight patients survived and/or completed the 6 month study protocol. Freedom from symptomatic recurrent biliary obstruction requiring re-intervention was achieved in 108 of 113 patients (95.6, 95%CI = 90.0-98.6%) at study exit for each patient. Per interval analysis yielded the absence of recurrent biliary obstruction in 99.0% of patients at 1 month (n = 99; 95%CI = 97.0-100%), 96.6% of patients at 3 months (n = 77; 95%CI = 92.7-100%), and 93.3% of patients at 6 months (n = 48; 95%CI = 86.8-99.9%). In total, only 5 patients (4.4%) were considered failures of the primary endpoint. Most of these failures (4/5) were due to stent occlusion from tumor ingrowth or overgrowth. Overall technical success rate of stent deployment was 99.2%. There were 2 cases of stent-related adverse events (1.8%). There were no cases of post-procedure stent migration, stent-related perforation, or stent-related deaths. CONCLUSIONS: This newly designed and marketed biliary SEMS system appears to be effective at relieving biliary obstruction and preventing re-intervention within 6 months of insertion in the overwhelming majority of patients. The device has an excellent safety profile, and associated high technical success rate during deployment. TRIAL REGISTRATION: The study was registered on clinicaltrials.gov on 14 October 2013 and the study registration number is NCT01962168. University of Massachusetts Medical School did not participate in the study.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".